99mTc-MAG3: Image Wisely
Andrew T Taylor1, Russell D Folks1, A K M Fazlur Rahman1
1From the Department of Radiology and Imaging Sciences (A.T.T., R.D.F., A.P., R.H.) and Department of Biostatistics and Bioinformatics (A.K.M.F.R., A.M.), Emory University School of Medicine, 1364 Clifton Rd, Atlanta, GA 30322; Veterans Administration Medical Center, Decatur, Ga (A.T.T.); and Departments of Biostatistics (A.K.M.F.R.) and Radiology (E.V.D.), University of Alabama, Birmingham, Ala.
Abstract:
Purpose To determine if commonly administered doses of technetium 99m (99mTc) mertiatide (MAG3) in the range of 300-370 MBq (approximately 8-10 mCi) contribute to image interpretation and justify the resulting radiation exposure. Materials and Methods The respective institutional review boards approved this HIPAA-compliant study and waived informed consent. Baseline and furosemide 99mTc-MAG3 imaging examinations in 50 patients suspected of having renal obstruction and 48 patients suspected of having renovascular hypertension (RVH) were randomly selected from archived databases and were independently scored by three experienced readers without access to 2-second flow images. Readers were blinded to their original scores, and then they rescored each examination with access to high-activity 2-second flow images. Relative renal function was determined after a low activity (62.9 MBq ± 40.7) baseline acquisition for RVH and a high activity (303.4 MBq ± 48.1) acquisition after administration of enalaprilat. Data were analyzed by using random effects analysis of variance and mean and standard error of the mean for the difference between sets of scores and the difference between relative function measurements. Results There was no significant difference in the scores without flow images compared with blinded scores with high-activity flow images for patients suspected of having obstruction (P = .80) or RVH (P = .24). Moreover, there was no significant difference in the relative uptake measurements after administration of low and high activities (P > .99). Conclusion Administered doses of 99mTc-MAG3 in the range of 300-370 MBq (approximately 8-10 mCi) do not affect the relative function measurements or contribute to interpretation of images in patients suspected of having RVH or obstruction compared with administration of lower doses; unnecessary radiation exposure can be avoided by administering doses in the range of 37-185 MBq as recommended incurrent guidelines. © RSNA, 2017.
Related Concept Videos
Photochemical Electrocyclic Reactions: Stereochemistry
Selection Rules: Photochemical Activation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Transmission Electron Microscopy
Photoelectric Effect