Objective:
A 66-year-old man underwent a placement of an inferior vena cava filter before a gastric surgery 9 years prior, presented to the emergency room with a complete atrioventricular block. Chest x-ray and transthoracic echocardiogram showed struts migrating to right ventricle with tricuspid regurgitation. Cardiothoracic surgery was consulted and declined an open surgical intervention due to the location of the embolized fragments and the patient's overall condition. It was also felt that the fragments had migrated chronically and were adhered to the cardiac structures.
Methods:
The patient underwent a dual-chamber permanent pacemaker implantation. Post-implant fluoroscopy showed no displacement of the inferior vena cava filter struts due to the pacemaker leads indicating that the filter fracture had likely been a chronic process.
Results:
This case highlights a rare combination of complications related to inferior vena cava filter fractures and the importance of assessing for such fractures in chronic placements. Inferior vena cava filter placement for a duration greater than 1 month can be associated with filter fractures and strut migration which may lead to, although rare, serious or fatal complications such as complete atrioventricular conduction system disruption and valvular damage including significant tricuspid regurgitation.
Conclusions:
Assessing for inferior vena cava filter fractures in chronic filter placement is important to avoid such complications. When possible, retrieval of the filter should be considered in all patients outside the acute setting in order to avoid filter-related complications. Filter retrieval rates remain low even when a retrievable filter is in place and the patient no longer has a contraindication to anticoagulation.
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Cardiac Catheterization III: Left Heart Catheterization
Pulmonary Embolism I: Introduction
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Catheterization I: Pre-Procedure Overview