Related Experiment Video
Updated: Mar 7, 2026

Method to Obtain Pattern of Breathing in Senescent Mice through Unrestrained Barometric Plethysmography
Published on: April 28, 2020
Linshom thermodynamic sensor is a reliable alternative to capnography for monitoring respiratory rate
David Preiss1, Benjamin A Drew2, James Gosnell1
1Department of Anesthesiology, Perioperative and Pain Medicine, Harvard Medical School/Brigham and Women's Hospital, Boston, MA, 02115, USA.
Abstract:
Monitoring ventilation accurately is a technically challenging, yet indispensable aspect of patient care in the intra- and post-procedural settings. A new prototypical device known as the Linshom Respiratory Monitoring Device (LRMD) has been recently designed to non-invasively, inexpensively, and portably measure respiratory rate. The purpose of this study was to measure the accuracy and variability of LRMD measurements of respiratory rate relative to the measurement of capnography. In this prospective study, participants were enrolled and individually fitted with a face mask monitored by the LRMD and capnography. With a baseline oxygen flow rate and digital metronome to pace their respiratory rate, the participants were instructed to breathe at 10 breaths per minute (bpm) for 3 min, 20 bpm for 3 min, 30 bpm for 3 min, 0 bpm for 30 s, and resume regular breathing for 30 s. Both sensors were connected to a computer for continuous temperature and carbon dioxide waveform recordings. The data were then retrospectively analyzed. Twenty-six healthy volunteers, mean (range) age 27.8 (23-37) and mean (range) BMI 23.1 (18.8-29.2) kg/m2 were recruited. There were 15 males (57.7%) and 11 females (42.3%). After excluding 3 subjects for technical reasons, 13,800 s of breathing and 4,140 expiratory breaths were recorded. Throughout the protocol, the average standard deviation (SD) for the LRMD and capnography was 1.11 and 1.81 bpm, respectively. The overall mean bias (±2SD) between LRMD and capnography was -0.33 (±0.1.56) bpm. At the lowest and intermediate breathing rates reflective of hypoventilation and normal ventilation, the LRMD variance was 0.55 and 1.23 respectively, compared to capnography with 5.54 and 7.47, respectively. At higher breathing rates indicative of hyperventilation, the variance of the test device was 4.52, still less than that of capnography at 5.73. This study demonstrated a promising correlation between the LRMD and capnography for use as a respiratory rate monitor. The LRMD technology may be a significant addition to monitoring vital signs because it offers a minimally intrusive opportunity to detect respiratory rate and apnea, without expensive or complex anesthetic equipment, before the need for life-saving resuscitation arises.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...