1From the *Duke Children's Hospital, Durham, North Carolina; †The Hospital for Sick Children, Toronto, Ontario, Canada; ‡St. Louis Children's Hospital, St. Louis, Missouri; §Cincinnati Children's Hospital, Cincinnati, Ohio; ¶Stanford University, Palo Alto, California; and ‖Texas Children's Hospital, Houston, Texas.
Abstract:
The Berlin Heart EXCOR Pediatric Ventricular Assist Device (BH) was approved for use in the United States in December 2011, based on a prospective investigational device exemption (IDE) trial. Strict exclusion criteria for the trial selected a low-risk "ideal" cohort. We sought to determine whether postapproval usage of the BH in a "real world" cohort of recipients would result in similar outcomes. Preimplant diagnostic information was collected for all patients. Efficacy was evaluated by comparison of all children (efficacy group, n = 247) implanted between FDA approval and April 2015 to those in the IDE trial (IDE, n = 48), with regard to achievement of one of four end-states: transplanted, successful weaning, death/unsuccessful weaning, or still-on-device. Safety outcomes were compared between IDE patients and a subset of postapproval patients (safety group, n = 39) for whom adjudicated adverse events were tracked in a regulator-mandated dataset. Diagnostic categories were similar between groups: IDE (congenital 19%, dilated cardiomyopathy/myocarditis/other 81%) versus Efficacy Group (congenital 24%, dilated cardiomyopathy/myocarditis/other 75%). Patients in the IDE cohort were larger (median 14.8 kg, range 3.6-58.1 kg vs. 10.7 kg, 2.9-112.0 kg, p = 0.02). More IDE patients were successfully supported than in the efficacy group cohort (90% vs. 77%, p = 0.05). Proportions with bleeding and stroke were similar between the IDE and safety group cohorts (46% vs. 41%, p = 0.65; 29% vs. 33%, p = 0.68, respectively). With usage of the BH in a less-ideal population, rates of bridge to transplant and weaning have declined slightly, but remain encouragingly high. Bleeding and neurologic event rates have not increased.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026