Related Experiment Video
Updated: Mar 7, 2026

Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
Published on: October 28, 2020
Clinical Implications of Three-Dimensional Real-Time Color Doppler Transthoracic Echocardiography in Quantifying
Ran Heo1, Jang-Won Son2, Briain Ó Hartaigh3
1Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea.
Background:
Automatic quantification of real-time three-dimensional (3D) full-volume color Doppler transthoracic echocardiography (FVCD) has been proposed as a feasible and accurate method for quantifying MR. We aimed to explore the clinical implications of real-time 3D-FVCD for mitral regurgitation (MR) with various clinical manifestations, in comparison with the conventional two-dimensional (2D) proximal isovelocity surface area (PISA) and volumetric method and cardiac magnetic resonance imaging (CMR) methods.
Methods:
A total 186 patients with MR were enrolled prospectively. Based on exclusion criteria and image quality review, 152 patients were included in the final analysis for 3D-FVCD and 2D transthoracic echocardiography. Among them, 37 patients underwent subsequent CMR for the validation of 3D-FVCD.
Results:
MR volume from 3D-FVCD demonstrated a better agreement (r = 0.94) with CMR than 2D-PISA or the 2D volumetric method (VM; r = 0.87 vs 0.56). Overall, 2D methods underestimated MR when compared with 3D-FVCD (35.4 ± 28.4 mL for 2D-VM vs 43.8 ± 24.6 mL for 2D-PISA vs 64.6 ± 35.1 mL for 3D-FVCD; P < .001). In subgroup analysis, multijet MR (odds ratio [OR], 6.30; 95% CI, 2.52-15.72) and dilated left ventricular end-systolic diameter ≥40 mm (OR, 2.90; 95% CI, 1.12-7.50) were predictors of significant difference in MR volume (>30 mL for primary MR and >15 mL for secondary MR) between 2D-PISA and 3D-FVCD. In identifying surgical candidates, patients with multijet MR (OR, 4.53, 95% CI, 1.99-10.35) demonstrated a higher risk of discrepancy between 2D-PISA and 3D-FVCD, which were consistent in both primary and secondary MR, respectively.
Conclusions:
MR quantification with 3D-FVCD showed better correlation and agreement than conventional 2D methods. MR was underestimated by 2D methods, especially in multijet and dilated left ventricle. Multijet MR demonstrated higher risk of discrepancy for the identification of surgical candidate, regardless of MR etiology.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Related Concept Videos
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Regurgitation III: Medical Management
Mitral Regurgitation I: Introduction
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Mitral Valve Prolapse II: Assessment and Management