Related Experiment Video
Updated: Mar 7, 2026

Preparation of Authigenic Pyrite from Methane-bearing Sediments for In Situ Sulfur Isotope Analysis Using SIMS
Published on: August 31, 2017
Rapid quantification and isotopic analysis of dissolved sulfur species
Derek A Smith1, Alex L Sessions1, Katherine S Dawson1
1Division of Geological and Planetary Sciences, California Institute of Technology, 1200 E California Blvd, Pasadena, CA, 91125, USA.
Rationale:
Dissolved sulfur species are of significant interest, both as important substrates for microbial activities and as key intermediaries in biogeochemical cycles. Species of intermediate oxidation state such as sulfite, thiosulfate, and thiols are of particular interest but are notoriously difficult to analyze, because of low concentrations and rapid oxidation during storage and analysis.
Methods:
Dissolved sulfur species are reacted with monobromobimane which yields a fluorescent bimane derivative that is stable to oxidation. Separation by Ultra-Performance Liquid Chromatography (UPLC) on a C18 column yields baseline resolution of analytes in under 5 min. Fluorescence detection (380 nm excitation, 480 nm emission) provides highly selective and sensitive quantitation, and Time-of-Flight Mass Spectrometry (TOF-MS) is used to quantify isotopic abundance, providing the ability to detect stable isotope tracers (either 33 S or 34 S).
Results:
Sulfite, thiosulfate, methanethiol, and bisulfide were quantified with on-column detection limits of picomoles (μM concentrations). Other sulfur species with unshared electrons are also amenable to analysis. TOF-MS detection of 34 S enrichment was accurate and precise to within 0.6% (relative) when sample and standard had similar isotope ratios, and was able to detect enrichments as small as 0.01 atom%. Accuracy was validated by comparison to isotope-ratio mass spectrometry. Four example applications are provided to demonstrate the utility of this method.
Conclusions:
Derivatization of aqueous sulfur species with bromobimane is easily accomplished in the field, and protects analytes from oxidation during storage. UPLC separation with fluorescence detection provides low-μM detection limits. Using high-resolution TOF-MS, accurate detection of as little as 0.01% 34 S label incorporation into multiple species is feasible. This provides a useful new analytical window into microbial sulfur cycling. Copyright © 2017 John Wiley & Sons, Ltd.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
08:01Sulfate Separation by Selective Crystallization with a Bis-iminoguanidinium Ligand
Published on: September 8, 2016
Related Concept Videos
Sulfur Assimilation
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Precipitation and Co-precipitation
The Sulfur Cycle