Related Experiment Video
Updated: Mar 6, 2026

CD Spectroscopy to Study DNA-Protein Interactions
Published on: February 10, 2022
Advantages of synchrotron radiation circular dichroism spectroscopy to study intrinsically disordered proteins
Patricia S Kumagai1, Ricardo DeMarco1, Jose L S Lopes2
1Instituto de Física de São Carlos, Universidade de São Paulo, São Carlos, Brazil.
Abstract:
The unordered secondary structural content of an intrinsically disordered protein (IDP) is susceptible to conformational changes induced by many different external factors, such as the presence of organic solvents, removal of water, changes in temperature, binding to partner molecules, and interaction with lipids and/or other ligands. In order to characterize the high-flexibility nature of an IDP, circular dichroism (CD) spectroscopy is a particularly useful method due to its capability of monitoring both subtle and remarkable changes in different environments, relative ease in obtaining measurements, the small amount of sample required, and the capability for sample recovery (sample not damaged) and others. Using synchrotron radiation as the light source for CD spectroscopy represents the state-of-the-art version of this technique with feasibility of accessing the lower wavelength UV region, and therefore presenting a series of advantages over conventional circular dichroism (cCD) to monitor a protein conformational behavior, check protein stability, detect ligand binding, and many others. In this paper, we have performed a comparative study using cCD and SRCD methods for investigating the secondary structure and the conformational behavior of natively unfolded proteins: MEG-14 and soybean trypsin inhibitor. We show that the SRCD technique greatly improves the analysis and accuracy of the studies on the conformations of IDPs.
More Related Videos
10:03Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
07:56Utilizing Time-Resolved Protein-Induced Fluorescence Enhancement to Identify Stable Local Conformations One α-Synuclein Monomer at a Time
Published on: May 30, 2021
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Intrinsically Disordered Proteins
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...