Related Experiment Video
Updated: Mar 6, 2026

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
Published on: August 24, 2018
The Effect of a CAD/CAM-Guided Template on Formation of the Screw-Access Channel for Fixed Prostheses Supported by
Purpose:
The aim of this study was to evaluate the effect of a computer-aided design/computer-assisted manufacturing (CAD/CAM) guide on drilling the screw-access channel for lingually placed implants.
Materials And Methods:
Screw-channel drilling guides were fabricated on lingually placed implant models using CAD/CAM technology. The screw channels were prepared with guided or freehand drilling by 20 dental graduates. The accuracy of each screw channel was assessed for drilling entry point, channel volume, and angulation (α = .05).
Results:
The guided drilling group showed smaller deviations than the freehand drilling group, and prosthesis position influenced the guide effect (P < .001).
Conclusion: