A temperature-controlled glove with non-invasive arterial pulse sensing for active neuro-vascular assessment
Abstract:
A non-invasive, active neuro-vascular assessment system was developed using a modified temperature-controlled glove and feedback techniques. The glove incorporates local heating and cooling of the hand using multi-point skin temperature measurements as feedback, and thereby induces local and central mechanisms involved in thermoregulation. Electrocardiogram (ECG), photoplethysmogram (PPG) and non-invasive finger-cuff based blood pressure (BP) measurements were used to monitor electrophysiology and hemodynamic changes in response to temperature modulation. Then, the triggered neuro-vascular mechanisms associated with thermoregulation were quantified by extracting parameters from the measured waveforms, specifically heart rate variability (HRV), vascular tone, and BP. The system was tested on six young, healthy individuals with no history of microvascular diseases. During heating, vasodilation, decrease in systolic BP, and a decrease in parasympathetic tone were observed, while during cooling, vasoconstriction and increased BP were observed. While such changes are expected physiologically using passive experiments, the ability to modulate the physiology non-invasively with a controlled, quantitative, and inexpensive instrument can potentially enable serial assessments of neuro-vascular control outside of clinical settings.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...