Related Experiment Video

Updated: Mar 6, 2026

An Implantable System For Chronic In Vivo Electromyography
09:52

An Implantable System For Chronic In Vivo Electromyography

Published on: April 21, 2020

11.4K

Implantable gastric electric stimulator with automatic daily activity compliance reporting

Eri Takami, Javier J Sanchez, Rose Province

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |March 9, 2017
    PubMed

    Abstract:

    In order for any obesity therapy to be successful real behavior change by the individual is required. We present an implantable obesity therapy that combines gastric electrical stimulation for satiety with onboard sensors that provide self-monitoring for the patient and compliance reporting to the clinician. An algorithm for processing data from the onboard three axis accelerometer for use in physical activity monitoring was developed and validated. Four obese patients participated in a study where self-reported sleep and exercise was compared with the events detected by the implanted system, and two commercially available, wearable activity monitors.

    More Related Videos

    Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
    08:17

    Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa

    Published on: September 27, 2018

    8.9K
    A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
    16:40

    A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

    Published on: February 28, 2012

    26.9K

    Related Experiment Videos

    Last Updated: Mar 6, 2026

    An Implantable System For Chronic In Vivo Electromyography
    09:52

    An Implantable System For Chronic In Vivo Electromyography

    Published on: April 21, 2020

    11.4K
    Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
    08:17

    Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa

    Published on: September 27, 2018

    8.9K
    A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
    16:40

    A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

    Published on: February 28, 2012

    26.9K

    Related Concept Videos

    Pulse rhythm01:30

    Pulse rhythm

    1.5K
    Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
    Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
    1.5K

    Articles linked to this work by shared authors, journal, and citation graph.

    Disinfection of needleless connectors for catheters in one second using a hand-held UV device.

    American journal of infection control·2024

    Side-to-side magnetic duodeno-ileostomy in adults with severe obesity with or without type 2 diabetes: early outcomes with prior or concurrent sleeve gastrectomy.

    Surgery for obesity and related diseases : official journal of the American Society for Bariatric Surgery·2023

    Combined Effect of Genetic Variants on Long-Term Weight Response after Bariatric Surgery.

    Journal of clinical medicine·2023

    Comparative analysis of 5-year efficacy and outcomes of single anastomosis procedures as revisional surgery for weight regain following sleeve gastrectomy.

    Surgical endoscopy·2023

    Side-to-side magnet anastomosis system duodeno-ileostomy with sleeve gastrectomy: early multi-center results.

    Surgical endoscopy·2023

    Influence of CLOCK Gene Variants on Weight Response after Bariatric Surgery.

    Nutrients·2022

    Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Fast disturbance rejection for inertial stabilization platforms based on a nonlinear adaptive sliding-mode-assisted disturbance observer.

    ISA transactions·2026

    MEYELens: An affordable, open-source, 3D-printable eyewear platform for pupillometry and gaze tracking.

    Behavior research methods·2026

    In-field temporal phase analysis of running: performance assessment of 36 IMU-based algorithms across different device positions and running speeds.

    Journal of biomechanics·2026

    A high-accuracy RFID system for efficient management of hospital textiles: design, implementation, and performance evaluation.

    Journal of medical engineering & technology·2026

    All-Inside Meniscus Repair Systems Failure Analysis Shows Device-Related Adverse Events Differ by Device Design Type and Show Varied Reporting Delays by Manufacturer.

    Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association·2026

    Engineering a Timing-Accurate VR-EEG-Oculomotor Fusion System for Objective Assessment of Executive Function in ADHD.

    IEEE transactions on bio-medical engineering·2026
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies
    Jove
    Visualize
    Contact Us