Disinfection of needleless connectors for catheters in one second using a hand-held UV device
Michael Fourkas1, Eri Takami1, Gregory J Schears2
1PuraCath Medical Inc., Newark, CA.
Background:
The standard of care for disinfecting needleless connectors (NCs) of central venous catheters includes alcohol-containing caps or up to a 15-second scrub with alcohol or chlorhexidine. Due to the clinical impact and high cost of treating Central line-associated bloodstream infections (CLABSI), reducing the incidence of CLABSI is a priority for public health and of the Centers for Disease Control. Alcohol-containing caps have been demonstrated to disinfect external NC surfaces, but not the internal surface. Ultraviolet light (UV-C) is a strategy for disinfection of NC internal and external surfaces.
Methods:
Four clinically relevant bacteria (Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Pseudomonas aeruginosa) and Candida albicans were inoculated on NCs. Disinfection efficacy was measured after exposure to one second of 285 nm UV-C light at 48 mW/cm2 in a proprietary handheld device and UV-C transparent NC or standard of care. Disinfection of internal and external surfaces of NC inoculated with S aureus using alcohol caps, and UV-C was also compared.
Results:
A 4-log reduction in colony forming units (CFUs) on the interior and exterior surfaces of the UV-transparent NC of clinically relevant pathogens was observed with UV-C light at this power for 1 second.
Discussion:
We demonstrated the efficacy of UV-C for the disinfection of NCs in one second using the UV-C device in benchtop studies.
Conclusions:
This device holds promise for reducing CLABSI, and clinical studies are planned.
More Related Videos
10:43High-throughput Identification of Bacteria Repellent Polymers for Medical Devices
Published on: November 5, 2016
07:34Isolation of Single Intracellular Bacterial Communities Generated from a Murine Model of Urinary Tract Infection for Downstream Single-cell Analysis
Published on: April 16, 2019
Related Concept Videos
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...