Related Experiment Video
Updated: Mar 6, 2026

Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Reliability of thermodilution derived cardiac output with different operator characteristics
Scott C McKenzie1,2, Kimble Dunster3, Wandy Chan1,2
1Faculty of Health Sciences, School of Medicine, The University of Queensland, Brisbane, QLD, Australia.
Thermodilution technique for cardiac output measurement shows reasonable accuracy, but operator experience is key. Increased right heart catheterisation experience significantly improves cardiac output measurement accuracy.
Area of Science:
- Cardiovascular Physiology
- Medical Device Technology
- Clinical Measurement
Background:
- Cardiac output (CO) is crucial for assessing hemodynamic status.
- Thermodilution is a common method for CO measurement during right heart catheterisation (RHC).
- Inter-operator variability in thermodilution CO measurements is not well-quantified.
Purpose of the Study:
- To assess inter-operator variability of the thermodilution technique for CO measurement.
- To identify operator characteristics influencing CO measurement accuracy.
- To compare thermodilution-derived CO with a calibrated mock circulation loop (MCL).
Main Methods:
- Utilized a mock circulation loop (MCL) with calibrated flow sensors to generate controlled CO levels (3.0–7.0 L/min).
- 15 participants (cardiologists, cardiology trainees, ICU consultants) performed thermodilution CO measurements.
- Recorded participant characteristics (experience, BMI, grip strength) and compared them to MCL-calibrated CO.
Main Results:
- Participants generally overestimated CO by a mean difference of +0.75 ± 0.71 L/min.
- The overall correlation between actual and measured CO was strong (r² = 0.85).
- Accuracy improved significantly with increased RHC experience, higher BMI, and decreased grip strength.
Conclusions:
- Thermodilution is a reasonable technique for CO determination.
- Operator experience is the primary factor linked to CO measurement accuracy.
- Adequate training and exposure to thermodilution are essential for clinicians performing RHC.
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...