Related Experiment Video
Updated: Mar 6, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Comparison of different techniques for removal of calcium hydroxide from straight root canals: an in vitro study
Anne-Kathrin Pabel1, Michael Hülsmann2
1Department of Preventive Dentistry, Periodontology and Cariology, University of Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
Abstract:
To compare four different techniques for removal of calcium hydroxide from straight root canals. The present study used the design suggested by Lee et al. (Int Endod J 37:607-612, 32) and van der Sluis et al. (Int Endod J 40:52-57, 17). One-hundred and ten extracted human teeth with straight root canals were prepared to ISO-size 50 and split longitudinally. Two lateral grooves were prepared, filled with calcium hydroxide and the root halves reassembled in a muffle. Calcium hydroxide was removed using one of five techniques: (1) passive ultrasonic irrigation, (2) hydrodynamic irrigation using RinsEndo®, (3) sonic irrigation using the EndoActivator®, (4) motor-driven plastic brush (CanalBrush™), and (5) manual irrigation with a syringe as the control group. Distilled water was used as irrigant. Cleanliness of the grooves was scored under a microscope with 40× magnification. For intraindividual reproducibility and interrater agreement, Cohens Kappa was calculated. Results of scoring were analyzed using a non-parametric test. Post hoc pairwise comparisons were used for irrigation techniques (α = 0.05). Passive ultrasonic irrigation performed significantly better than all other groups in the apical groove. Significant differences were found between RinsEndo and CanalBrush (P = 0.01855) and CanalBrush and syringe irrigation (P = 0.00021). In the coronal groove, passive ultrasonic irrigation performed significantly superior and hand irrigation performed significantly worse than all other groups. A statistically significant interaction was shown between irrigation technique and localization of the groove (P = 0.01358). The coronal grooves showed more remaining calcium hydroxide than the apical grooves. Complete removal of calcium hydroxide from the root canal could not be achieved with any of the techniques investigated. The highest degree of cleanliness resulted from the use of passive ultrasonic irrigation.
Related Concept Videos
Factors Affecting Solubility
Hydration of Cement
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Skeleton and Calcium Homeostasis

