Related Experiment Video
Updated: Mar 6, 2026

Simultaneous ex vivo Functional Testing of Two Retinas by in vivo Electroretinogram System
Published on: May 6, 2015
Test-retest reliability of scotopic full-field electroretinograms in rabbits
Jan Luebke1,2, Alexandra Anton3,4, Michael Bach3,4
1Eye Center, Medical Center, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany. jan.luebke@uniklinik-freiburg.de.
Purpose:
To explore test-retest reliability of standard scotopic full-field ERG measurements in New Zealand White rabbits. The ERG is widely used for testing of retinal integrity after any ocular treatment. We here present detailed stimulus-response dependencies for single healthy and untreated animals, concentrating on test-retest reproducibility.
Materials And Methods:
Five New Zealand White rabbits (aged 8-10 weeks, weight about 2.0-2.5 kg) underwent binocular ERG measurements after intramuscular anesthesia and pharmaceutical pupillary dilatation at a baseline day and 10 days later. Eleven scotopic flash strengths (0.0001-10 cd s/m2) were presented. Variability was quantified via the 95% limits of agreement (LOA).
Results:
The a-waves displayed the typical monotonic sigmoid amplitude increase with flash strength, and the b-waves peaked at 0.01 cd s/m2, followed by a marked dip at 0.1-0.3 cd s/m2. LOA of both waves went through a maximum in the dip region. LOA divided by mean amplitudes (relative LOA) was fairly flat over flash strength, around 20% beyond the dip. Intraindividual interocular variability was markedly lower, around 10%.
Conclusions:
Scotopic ERG responses in rabbits display a region of high variability at 0.1-0.3 cd s/m2; beyond that region the amplitude-LOA is 20%, the interocular LOA being half that value. The use of intraindividual control eyes for testing any toxicity of ocular agents thus appears markedly more sensitive. As a rule of thumb, we found the relative 95% LOA as 33% between individuals, 20% across sessions and 10% between eyes.

