Related Experiment Video
Updated: Mar 6, 2026

An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Fenestrated Screws Augmented With PMMA Increase the Pullout Strength of Sacral Pedicle Screws
Matthew Colman1, Jonathan Pond, Kent Bachus
1*Departments of Orthopaedic Surgery, University of Utah, Salt Lake City, UT †Aurora Sheboygan Medical Center, Sheboygan, WI.
Study Design:
Biomechanics.
Objective:
The objective of this study was to compare the fixation in osteoporotic specimens of a bicortical sacral pedicle screw to the following constructs: a unicortical solid screw augmented with polymethylmethacrylate (PMMA) (TRACT), a unicortical fenestrated screw augmented with PMMA (FEN), and a bicortical screw/sacral alar screw combination (PED/ALA).
Summary Of Background Data:
Rigid posterior sacral fixation of osteoporotic spines is problematic due to poor bone quality. Options to improve fixation include bicortical or tricortical screw trajectory, addition of S2 alar screws, or PMMA augmentation.
Materials And Methods:
Eleven osteoporotic cadaveric sacra were potted in 2-part filler compound. As a baseline fixation method, a 6.5-mm bicortical pedicle screw was placed into 1 pedicle of each sacra. The contralateral side was randomly assigned to receive a unicortical fenestrated 6.5-mm pedicle screw augmented with PMMA, a unicortical solid 6.5-mm pedicle screw augmented with PMMA, or a bicortical pedicle screw/alar screw construct. Pedicle screws were failed in cantilever pullout using a materials testing machine. Data were normalized into a test index by taking the ratio of the test screw pullout strength to the intraspecimen bicortical control screw pullout strength.
Results:
The fixation strengths as expressed by the test index of the TRACT, FEN, and PED/ALA groups were 101%, 157%, and 167%, respectively. Although there was no statistical difference detected between the FEN and PED/ALA groups, the TRACT group had a trend toward lower pullout strength than the FEN (P=0.06) or PED/ALA (0.06) groups. Although underpowered, this study did not detect biomechanical inferiority for any of the 3 test configurations when compared with standard bicortical S1 screws.
Conclusions:
The data indicate that the fixation strength of a fenestrated, PMMA-augmented construct or a combined S1 pedicle/S2 alar screw construct may be better than either standard bicortical or unicortical PMMA screw-tract augmented screws.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022