Related Experiment Video
Updated: Mar 5, 2026

Measurement of Spatial Stability in Precision Grip
Published on: June 4, 2020
Burn Hand or Finger Goniometric Measurements: Sum of the Isolated Parts and the Composite Whole
Reg Richard1, Ingrid S Parry, Alexis Santos
1From the *Burn Rehabilitation Department, JBSA Fort Sam Houston, Texas; †Research Department, University of California - Davis, Sacramento, California; and ‡Department of Statistics, Pennsylvania State University, University Park.
Abstract:
Accurate assessment of hand function following a burn is important for patient impairment determination. Goniometric measurement of hand or finger range of motion (ROM) is typically done measuring individual finger joints with the adjacent joint in extension (isolated) or measuring the joints in a fist position (composite). The purpose of this study was to compare if the total flexion motion of the summed angles of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints in burned hands were equal when performed in an isolated vs a composite manner. Passive flexion ROM angles were collected prospectively and measured at the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal with the adjacent joints extended to measure isolated angles and with the adjacent joints fully flexed for composite angles. Thumb joints were excluded. ROM for isolated and composite positions of eight fingers was compared individually and as an aggregate. Finger measurements from 145 adult patients were compared. The study population was predominately male (69%) with a mean age of 41 ± 16.6 years. Mean total burn size was 14.2 ± 13.2%. A total of 739 fingers contributed 2217 joint ROM comparisons. Aggregate analysis of isolated ROM was 235.5° ± 52.1° compared with composite ROM of 226.8° ± 53.2° (P < .0001). Individual fingers showed significant differences between the two measurement methods as well (P ≤ .0040). The methods used to measure hand or finger ROM profoundly influence how hand impairment is reported. Measurement of isolated joint angles results in greater ROM values compared with composite angles, which are often more relevant for functional hand positions. Therefore, composite angles are recommended.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:

