Related Experiment Video

Updated: Mar 5, 2026

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases
09:55

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases

Published on: January 5, 2024

1.9K

No-Reference Quality Assessment of Tone-Mapped HDR Pictures

Debarati Kundu, Deepti Ghadiyaram, Alan C Bovik

    IEEE Transactions on Image Processing : a Publication of the IEEE Signal Processing Society
    |March 24, 2017
    PubMed

    Abstract:

    Being able to automatically predict digital picture quality, as perceived by human observers, has become important in many applications where humans are the ultimate consumers of displayed visual information. Standard dynamic range (SDR) images provide 8 b/color/pixel. High dynamic range (HDR) images, which are usually created from multiple exposures of the same scene, can provide 16 or 32 b/color/pixel, but must be tonemapped to SDR for display on standard monitors. Multi-exposure fusion techniques bypass HDR creation, by fusing the exposure stack directly to SDR format while aiming for aesthetically pleasing luminance and color distributions. Here, we describe a new no-reference image quality assessment (NR IQA) model for HDR pictures that is based on standard measurements of the bandpass and on newly conceived differential natural scene statistics (NSS) of HDR pictures. We derive an algorithm from the model which we call the HDR IMAGE GRADient-based Evaluator. NSS models have previously been used to devise NR IQA models that effectively predict the subjective quality of SDR images, but they perform significantly worse on tonemapped HDR content. Toward ameliorating this we make here the following contributions: 1) we design HDR picture NR IQA models and algorithms using both standard space-domain NSS features as well as novel HDR-specific gradient-based features that significantly elevate prediction performance; 2) we validate the proposed models on a large-scale crowdsourced HDR image database; and 3) we demonstrate that the proposed models also perform well on legacy natural SDR images. The software is available at: http://live.ece.utexas.edu/research/Quality/higradeRelease.zip.

    More Related Videos

    Applying Hyperspectral Reflectance Imaging to Investigate the Palettes and the Techniques of Painters
    07:05

    Applying Hyperspectral Reflectance Imaging to Investigate the Palettes and the Techniques of Painters

    Published on: June 18, 2021

    2.9K
    Measuring Spatially- and Directionally-varying Light Scattering from Biological Material
    11:57

    Measuring Spatially- and Directionally-varying Light Scattering from Biological Material

    Published on: May 20, 2013

    14.0K

    Related Experiment Videos

    Last Updated: Mar 5, 2026

    Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases
    09:55

    Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases

    Published on: January 5, 2024

    1.9K
    Applying Hyperspectral Reflectance Imaging to Investigate the Palettes and the Techniques of Painters
    07:05

    Applying Hyperspectral Reflectance Imaging to Investigate the Palettes and the Techniques of Painters

    Published on: June 18, 2021

    2.9K
    Measuring Spatially- and Directionally-varying Light Scattering from Biological Material
    11:57

    Measuring Spatially- and Directionally-varying Light Scattering from Biological Material

    Published on: May 20, 2013

    14.0K

    Related Concept Videos

    Pulse amplitude and quality01:17

    Pulse amplitude and quality

    3.4K
    Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
    A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
    3.4K

    Articles linked to this work by shared authors, journal, and citation graph.

    Context-specific image quality assessment for virtual histologic staining: checklist and guideline.

    Journal of medical imaging (Bellingham, Wash.)·2026

    Intraoperative Hypotension and Risk of Cuff Blood Pressure Inaccuracy.

    medRxiv : the preprint server for health sciences·2026

    Joint Quality Assessment and Example-Guided Tone Mapping by Disentangling Picture Appearance From Content.

    IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

    Quality Prediction of Embedded and Overlaid Text in User-Generated Visual Content.

    IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

    SAMScore: A Content Structural Similarity Metric for Image Translation Evaluation.

    IEEE transactions on artificial intelligence·2026

    HoloQA: Full Reference Video Quality Assessor of Rendered Human Avatars in Virtual Reality.

    IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

    Unity in Diversity: Multi-expert Knowledge Adversarial Learning and Collaboration for Generalizable Vehicle Re-identification.

    IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

    TextBridge-Track: Hierarchical Spatio-temporal Alignment for RGBE Tracking via CLIP's Textual Guidance.

    IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

    Preserving Fairness in Knowledge Transfer for Exemplar-Free Class-Incremental Learning via Semantic Propagation.

    IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

    Integer-Transform Fractional-Order Spectrum of Cumulant for Star Image Restoration.

    IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

    Efficient High-Frequency Event-Based Optical Flow with Temporal Iterative Refinement and Spiking Neural Networks.

    IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

    MvT: Event-based Multi-view Projection for Multiple Object Tracking.

    IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026

    Impact of clear aligner (Invisalign®) treatment and occlusal changes on the masticatory function and temporomandibular disorders: A cross-sectional study.

    Dental and medical problems·2026

    MAC-DiffCT: Multi-Scale Adaptive Conditional Diffusion Model for CT Reconstruction from Biplanar X-rays.

    IEEE journal of biomedical and health informatics·2026

    Intraoperative cone-beam CT for real-time quality control in CSF shunt surgery: a prospective workflow study.

    Brain & spine·2026

    Hypervision: An on-chip hyperspectral microsystem for online video-rate computational imaging.

    Science (New York, N.Y.)·2026

    A Method for Generating Real-Time Indoor Illuminance Maps Based on Images in a Sensorless Lighting Environment.

    Sensors (Basel, Switzerland)·2026

    Multi-scale optical scanning holography for robust manipulation detection in satellite images.

    Scientific reports·2026
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies
    Jove
    Visualize
    Contact Us