[Occupational exposure in orthopedic procedures under fluoroscopic control].
Edyta Owsiak1, Renata Kopeć2, Maciej Budzanowski2
1Uniwersytecki Szpital Kliniczny im. Wojskowej Akademii Medycznej - Centralny Szpital Weteranów / University Clinical Hospital Military Memorial Medical Academy - Central Veterans' Hospital, Łódź, Poland (Klinika Ortopedii, Traumatologii i Rehabilitacji Pourazowej / Clinic of Orthopedy, Traumatology and Traumatic Rehabilitation).
Radiation exposure for orthopedic teams using X-rays is within normal ranges. Thermoluminescent dosimetry effectively monitors occupational doses, confirming safe practices in interventional radiology.
Area of Science:
- Medical Physics
- Occupational Health
- Radiology
Background:
- Interventional radiology procedures often result in high radiation doses for both patients and medical staff.
- Orthopedic procedures utilizing X-ray control are common across various medical specializations.
- This study focuses on evaluating radiation exposure specifically for interventional teams performing orthopedic procedures.
Purpose of the Study:
- To measure and assess radiation doses received by interventional teams during orthopedic procedures under X-ray guidance.
- To compare these doses with established reference levels and literature values.
- To validate the effectiveness of thermoluminescent dosimetry for monitoring occupational exposure in this setting.
Main Methods:
- Radiation dose equivalents were measured for interventional teams in three hospitals in Łódź.
- Thermoluminescent dosemeters were used to record dose equivalents for the eye lens (Hp(3)), palm skin (Hp(0.07)), neck (Hp(10) without collar), and whole body (Hp(10) under apron).
- Measurements were taken during 95 orthopedic procedures.
Main Results:
- The highest radiation doses were observed in the operator.
- The dose to the eye lens per procedure did not exceed 0.1 mSv.
- The highest recorded dose to the hands was 1.6 mSv, and the highest effective dose was 0.02 mSv.
Conclusions:
- The measured radiation doses for orthopedic interventional teams fall within the published reference ranges for non-vascular procedures.
- These findings demonstrate that practices in the studied Łódź hospitals align with standard methodologies in other interventional departments.
- Thermoluminescent dosimetry is confirmed as adequate for evaluating radiation exposure in interventional radiology, with a recommendation for using at least two dosemeters per staff member.