Related Experiment Video
Updated: Aug 13, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Simultaneous determination of the full chlorophenol spectrum in human urine using gas chromatography with tandem mass
1Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, Friedrich-Alexander-Universität Erlangen-Nürenberg, Schillerstrasse 25/29, 91054 Erlangen, Germany.
Abstract:
The determination of chlorophenols in urine is an established approach for the assessment of human exposure to these ubiquitous environmental pollutants. However, an analytical procedure which enables the separate determination of all components of this substance group was still lacking. For this task we developed a method using enzymatic hydrolysis, solid phase extraction, derivatisation with bis(trimethylsilyl)trifluoroacetamide and gas chromatography-tandem-mass spectrometry with isotope dilution. The chromatographic conditions provided baseline separation of all 19 chlorophenol derivatives. Precision within series did not exceed 15% although for urinary concentrations of 1 μg L-1. The recovery was found to be well for most of the parameters. Limits of quantifications ranged between 0.04 and 0.10 μg L-1. The present method is the first procedure which enables the simultaneous trace analysis of the full spectrum of chlorophenols in human urine. Thus, it may be a suitable benchmark procedure for the human biomonitoring of the exposure to these compounds in population studies.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors