Related Experiment Video
Updated: Jul 24, 2026

Characterization of Complex Systems Using the Design of Experiments Approach: Transient Protein Expression in Tobacco as a Case Study
Published on: January 31, 2014
Uncertainty quantification and design-of-experiment in absorption-based aqueous film parameter measurements using
Abstract:
Diode laser-based multi-wavelength near-infrared (NIR) absorption in aqueous films is a promising diagnostic for making temporally resolved, simultaneous measurements of film thickness, temperature, and concentration of a solute. Our previous work in aqueous urea solutions aimed at determining simultaneously two of these system parameters, while the third one must be fixed or specified by additional measurements. The current work presents a simultaneous NIR absorption-based multi-parameter measurement of thickness, temperature, and solute concentration coupled with the Bayesian methodology that is used to infer probability densities for the obtained data. The Bayesian analysis is based on a temperature- and concentration-dependent spectral database generated with a Fourier transform infrared spectrometer in the range 5500-8000 cm-1 for water with variable temperature and urea concentration. The concept was first validated with measurements using a calibration cell. Probability densities in the measured parameters were quantified using a Markov chain Monte Carlo algorithm, which were used to derive credibility intervals. As a practical demonstration, the temporal variation of film thickness, urea concentration, and liquid temperature were recorded during evaporation of a liquid film deposited on a transparent heated quartz plate.
More Related Videos
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
The Uncertainty Principle
Uncertainty: Overview
Propagation of Uncertainty from Random Error
Propagation of Uncertainty from Systematic Error
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...