A Simple Measure to Assess Hyperinflation and Air Trapping: 1-Forced Expiratory Volume in Three Second / Forced Vital
Sermin Börekçi1, Tunçalp Demir1, Aslı Görek Dilektaşlı2
1Department of Pulmonology, İstanbul University Cerrahpaşa School of Medicine, İstanbul, Turkey.
Background:
Several recent studies have suggested that 1 minus-forced expiratory volume expired in 3 seconds / forced vital capacity (1-FEV3/FVC) may be an indicator of distal airway obstruction and a promising measure to evaluate small airways dysfunction.
Aims:
To investigate the associations of 1-FEV3/FVC with the spirometric measures and lung volumes that assess small airways dysfunction and reflects hyperinflation and air trapping.
Study Design:
Retrospective cross-sectional study.
Methods:
Retrospective assessment of a total of 1110 cases who underwent body plethysmographic lung volume estimations between a time span from 2005 to 2012. Patients were assigned into two groups: firstly by FEV1/FVC (FEV1/FVC <70% vs. FEV1/FVC ≥70%); secondly by FEV3/FVC < lower limits of normal (LLN) (FEV3/FVC < LLN vs. FEV3/FVC ≥ LLN). Spirometric indices and lung volumes measured by whole-body plethysmography were compared in groups. Also the correlation of spirometric indices with measured lung volumes were assessed in the whole-study population and in subgroups stratified according to FEV1/FVC and FEV3/FVC.
Results:
Six hundred seven (54.7%) were male and 503 (45.3%) were female, with a mean age of 52.5±15.6 years. Mean FEV3/FVC and 1-FEV3/FVC were 87.05%, 12.95%, respectively. The mean 1-FEV3/FVC was 4.9% in the FEV1/FVC ≥70% group (n=644) vs. 24.1% in the FEV1/FVC <70% group (n=466). A positive correlation was found between 1-FEV3/FVC and residual volume (r=0.70; p<0.0001), functional residual capacity-pleth (r=0.61; p<0.0001), and total lung capacity (r=0.47; p<0.0001). 1-FEV3/FVC was negatively correlated with forced expiratory flow25-75 (r=-0.84; p<0.0001). The upper limit of 95% confidence interval for 1-FEV3/FVC was 13.7%. 1-FEV3/FVC showed significant correlations with parameters of air trapping and hyperinflation measured by whole-body plethysmography. Importantly, these correlations were higher in study participants with FEV1/FVC <70% or FEV3/FVC < LLN compared to those with FEV1/FVC ≥70% or FEV3/FVC ≥ LLN, respectively.
Conclusion:
1-FEV3/FVC can be easily calculated from routine spirometric measurements. 1-FEV3/FVC is a promising marker of air trapping and hyperinflation. We suggest that 1-FEV3/FVC is complementary to FEV1/FVC and recommend clinicians to routinely report and evaluate together with FEV1/FVC during spirometry.
More Related Videos
08:44Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
04:16Inspiratory Muscle Training as an Adjunct to the Treatment of Weaning Failure in Critically Ill Patients: A Practical Guide
Published on: January 30, 2026
Related Concept Videos
Lung Capacity
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Respiratory Volumes and Capacities
Acute Respiratory Failure-III