Related Experiment Videos
Averaged axillary F-loop latency of median and ulnar nerves
Abstract:
Axillary F-loop latencies (AFLL) were measured on median and ulnar nerves of 54 normal volunteers. The median and ulnar nerves were stimulated at the wrist and at the axilla 25cm distal to the sternal notch. The compound muscle action potentials were recorded from thenar and hypothenar muscles. Averaged tracings from 32 consecutive stimuli at the wrist were obtained. The averaged F-wave latencies were measured to the peak (Fwp) of the averaged F-wave. The M-wave latencies from wrist and axilla stimulation were measured to the onset of the wave (Mw and Ma, respectively). The averaged AFLL (a-AFLL) was calculated as (Fwp + Mw)-2 Ma. The average values of a-AFLL were 14.12 +/- 0.88msec for median nerve, and 13.97 +/- 0.90msec for ulnar nerve. There was no significant difference between male and female subjects, nor between the right and left sides. Seven subjects with EMG evidence of C8 or C8 to T1 radiculopathy, although manifesting normal AFLL gauged by the regular method (ie, measured to the onset of the shortest F-wave latency among eight tracings), had significantly longer "averaged AFLL" in both median and ulnar nerves of the affected side than the a-AFLL obtained from the normal side. It is concluded that the a-AFLL is a more sensitive measure than the "regular AFLL" in the assessment of proximal nerve lesion (especially C8 or C8 to T1 radiculopathy).