Related Experiment Video
Updated: Mar 3, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Influence of Different Pretreatments on the Microtensile Bond Strength to Eroded Dentin
Purpose:
To evaluate the influence of different pretreatments on the microtensile bond strength (µTBS) of an etch-and-rinse adhesive to eroded dentin.
Materials And Methods:
Thirty-six human teeth were ground down to their dentin layer and randomly divided into six groups (G1-G6; n = 6), G1 being the control group. Only in the test groups (G2-G6) were samples subjected to erosion using citric acid (pH 2.6) 10 x 2 min per day for five days. Between the erosive attacks, samples were stored in artificial saliva. After pretreatment - none (G1); none (G2); 2% chlorhexidine (30 s) (G3); prolonged primer application (1 min) (G4); roughening with a diamond bur (G5) and 10.5% NaOCl (1 min) (G6) - the adhesive OptiBond FL was applied. After the application of composite, samples were stored in water (7 d) and µTBS was determined. Data were evaluated using one-way ANOVA and Dunnett-T post-hoc test (p < 0.05).
Results:
Eroded dentin without pretreatment (G2) resulted in significant reduction of µTBS compared with uneroded dentin (G1). µTBS after pretreatment with a diamond bur (G5) or NaOCl (G6) was not significantly different from that of the uneroded control group (G1). µTBS after pretreatment with chlorhexidine (G3) or with prolonged primer application (G4) was significantly lower than in the uneroded control group (G1), and not significantly different from the eroded control group (G2).
Conclusion:
The present data suggests that µTBS to eroded dentin pretreated with bur abrasion or NaOCl is similar to the µTBS to sound, uneroded dentin.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Bonding and Strength of Aggregate
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...