Purpose:
To study the distribution of macular ganglion cell-inner plexiform layer (GC-IPL) thickness and peripapillary retinal nerve fiber layer (RNFL) thickness in children with refractive errors.
Materials And Methods:
Two hundred forty-three healthy eyes from 139 children with refractive error ranging from -10.00 to +5.00 D were recruited from the National University Hospital Eye Surgery outpatient clinic. After a comprehensive ocular examination, refraction, and axial length (AL) measurement (IOLMaster), macular GC-IPL and RNFL thickness values were obtained with a spectral domain Cirrus high definition optical coherence tomography system (Carl Zeiss Meditec Inc.). Only scans with signal strength of >6/10 were included. Correlation between variables was calculated using the Pearson correlation coefficient. A multivariate analysis using mixed models was done to adjust for confounders.
Results:
The mean spherical equivalent refraction was -3.20±3.51 D and mean AL was 24.39±1.72 mm. Average, minimum, superior, and inferior GC-IPL were 82.59±6.29, 77.17±9.65, 83.68±6.96, and 81.64±6.70 μm, respectively. Average, superior, and inferior peripapillary RNFL were 99.00±11.45, 123.20±25.81, and 124.24±22.23 μm, respectively. Average, superior, and inferior GC-IPL were correlated with AL (β=-2.056, P-value 0.000; β=-2.383, P-value 0.000; β=-1.721, P-value 0.000), but minimum GC-IPL was not (β=-1.056, P-value 0.115). None of the RNFL parameters were correlated with AL.
Conclusions:
This study establishes normative macular GC-IPL and RNFL thickness in children with refractive errors. Our results suggest that high definition optical coherence tomography RNFL parameters and minimum GC-IPL are not affected by AL or myopia in children, and therefore warrants further evaluation in pediatric glaucoma patients.
More Related Videos
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Related Concept Videos
Anatomy of the Eyeball
Focusing of Light in the Eye
Photoreceptors and Visual Pathways