Related Experiment Video For 18F-DCFPyL
Updated: Mar 3, 2026

Automation of a Positron-emission Tomography PET Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
18F-DCFPyL PET/CT in the Detection of Prostate Cancer at 60 and 120 Minutes: Detection Rate, Image Quality, Activity
Maurits Wondergem1,2, Friso M van der Zant3, Remco J J Knol3
1Department of Nuclear Medicine, Noordwest Ziekenhuisgroep locatie Alkmaar, Alkmaar, The Netherlands M.Wondergem@nwz.nl.
Abstract:
There is increasing interest in PET/CT with prostate-specific membrane antigen (PSMA) tracers for imaging of prostate cancer because of the higher detection rates of prostate cancer lesions than with PET/CT with choline. For 68Ga-PSMA-11 tracers, late imaging at 180 min after injection instead of imaging at 45-60 min after injection improves the detection of prostate cancer lesions. For 18F-DCFPyL, improved detection rates have recently been reported in a small pilot study. In this study, we report the effects of PET/CT imaging at 120 min after injection of 18F-DCFPyL in comparison to images acquired at 60 min after injection in a larger clinical cohort of 66 consecutive patients with histopathologically proven prostate cancer. Methods: Images were acquired 60 and 120 min after injection of 18F-DCFPyL. We report the positive lesions specified for anatomic locations (prostate, seminal vesicles, local lymph nodes, distant lymph nodes, bone, and others) at both time points by visual analysis, the image quality at both time points, and a semiquantitative analysis of the tracer activity in both prostate cancer lesions as well as normal tissues at both time points. Results: Our data showed a significantly increasing uptake of 18F-DCFPyL between 60 and 120 min after injection in 203 lesions characteristic for prostate cancer (median, 10.78 vs. 12.86, P < 0.001, Wilcoxon signed-rank test). By visual analysis, 38.5% of all patients showed more lesions using images at 120 min after injection than using images at 60 min after injection, and in 9.2% a change in TNM staging was found. All lesions seen on images 60 min after injection were also visible on images 120 min after injection. A significantly better mean signal-to-noise ratio of 11.93 was found for images acquired 120 min after injection (P < 0.001, paired t test; signal-to-noise ratio at 60 min after injection, 11.15). Conclusion:18F-DCFPyL PET/CT images at 120 min after injection yield a higher detection rate of prostate cancer characteristic lesions than images at 60 min after injection. Further studies are needed to elucidate the best imaging time point for 18F-DCFPyL.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET