Related Experiment Video
Updated: Mar 3, 2026

Purification of Pathogen Vacuoles from Legionella-infected Phagocytes
Published on: June 19, 2012
UV-C inactivation of Legionella rubrilucens
Julian Schmid1, Katharina Hoenes1, Monika Rath1
1Ulm University of Applied Sciences, Ulm, Germany.
Abstract:
Background: Despite the great health significance of Legionella, there is only little information on their UV sensitivity. Besides Legionella pneumophila only L. longbeachae has been investigated so far. Methods: In this study L. rubrilucens has been spread on buffered charcoal yeast extract agar and irradiated with the 254 nm UV-C emission of a mercury vapor lamp. The disinfection success is measured by colony counting after incubation and comparison of the number of colonies on irradiated and unirradiated reference agar plates. Results: The average log-reduction dose is 1.08 mJ/cm2 for free L. rubrilucens, which is at the lower end of the so far published Legionella log-reduction values, but all three Legionella species show similar UV-C sensitivities. Conclusion: The log-reduction dose of legionellae in amoebae has not been investigated, but with the observed high UV-C sensitivity for free Legionella, the idea of a future point-of-use disinfection by small UV-C LEDs in water-taps or shower heads appears to be realistic, even if legionellae are more resistant in amoebae.