Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Comprehensive two-dimensional gas chromatography: A perspective on processes of modulation.
1Dipartimento di Scienze Chimiche, Biologiche, Farmaceutiche ed Ambientali, University of Messina, Polo Annunziata, viale Annunziata, 98168 Messina, Italy.
Comprehensive two-dimensional gas chromatography (GC×GC) relies on modulators to transfer column effluent. Future modulator developments could significantly expand the use of GC×GC technologies.
Area of Science:
- Analytical Chemistry
- Chromatography
Background:
- The first comprehensive two-dimensional gas chromatography (GC×GC) experiment was reported 25 years ago.
- The GC×GC technique requires a modulator for transferring effluent between columns.
Purpose of the Study:
- To explore future scenarios for modulation techniques in comprehensive GC.
- To discuss how advancements in modulation may increase GC×GC adoption.
Main Methods:
- Review of existing modulation systems.
- Discussion of potential future developments in modulation technology.
Main Results:
- Modulation is crucial for GC×GC operation, enabling sequential column re-injection.
- Cryogenic modulators are currently the most effective and popular.
Conclusions:
- Novel modulation strategies are key to unlocking broader applications of GC×GC.
- Future innovations in modulation promise to enhance the utility of comprehensive GC.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...