Related Experiment Video
Updated: Mar 3, 2026

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
Edge-preserving reconstruction from sparse projections of limited-angle computed tomography using ℓ0-regularized
Wei Yu1, Chengxiang Wang2, Min Huang3
1School of Biomedical Engineering, Hubei University of Science and Technology, Xianning 437100, China.
Abstract:
Accurate images reconstructed from limited computed tomography (CT) data are desired when reducing the X-ray radiation exposure imposed on patients. The total variation (TV), known as the l1-norm of the image gradient magnitudes, is popular in CT reconstruction from incomplete projection data. However, as the projection data collected are from a sparse-view of the limited scanning angular range, the results reconstructed by a TV-based method suffer from blocky artifact and gradual changed artifacts near the edges, which in turn make the reconstruction images degraded. Different from the TV, the ℓ0-norm of an image gradient counts the number of its non-zero coefficients of the image gradient. Since the regularization based on the ℓ0-norm of the image gradient will not penalize the large gradient magnitudes, the edge can be effectively retained. In this work, an edge-preserving image reconstruction method based on l0-regularized gradient prior was investigated for limited-angle computed tomography from sparse projections. To solve the optimization model effectively, the variable splitting and the alternating direction method (ADM) were utilized. Experiments demonstrated that the ADM-like method used for the non-convex optimization problem has better performance than other classical iterative reconstruction algorithms in terms of edge preservation and artifact reduction.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...