Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

1.3K
This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
1.3K
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

375
Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
375
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

796
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
796
Statically Indeterminate Problem Solving01:16

Statically Indeterminate Problem Solving

794
Statically indeterminate problems are those where statics alone can not determine the internal forces or reactions. Consider a structure comprising two cylindrical rods made of steel and brass. These rods are joined at point B and restrained by rigid supports at points A and C. Now, the reactions at points A and C and the deflection at point B are to be determined. This rod structure is classified as statically indeterminate as the structure has more supports than are necessary for maintaining...
794

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Automated dose-gradient curve and dose-volume histogram analysis platform: development, validation, and clinical decision support with TG-119 datasets.

Frontiers in oncology·2026
Same author

A proof-of-concept automated method for accurate skin dosimetry: correcting overestimated surface dose measurements.

Physics in medicine and biology·2026
Same author

A feasibility study on a machine-learning-based quality assurance tool for spot-scanning proton therapy using delivery log files and treatment plans.

Physics and imaging in radiation oncology·2026
Same author

Susceptibility of Large Language Models to User-Driven Factors in Medical Queries.

Journal of healthcare informatics research·2026
Same author

Comparative analysis of radiation therapy plans before and after biodegradable hydrogel (SpaceOAR) injection for reducing rectal toxicity in patients with prostate cancer undergoing carbon ion radiotherapy.

Frontiers in oncology·2026
Same author

Development and validation of an automated, accurate in-house treatment planning system for pencil-beam scanning carbon ion radiotherapy.

Medical physics·2026
Same journal

TRAIL-R2 in the shadows: Epigenetic silencing and clinical implications in breast cancer.

Oncotarget·2026
Same journal

Laryngeal leiomyosarcoma: A rare case report and literature review.

Oncotarget·2026
Same journal

DHHC3 interferes with antitumor immunity in melanoma cells.

Oncotarget·2026
Same journal

A randomized double-blind placebo-controlled phase I/II clinical trial of a human papillomavirus therapeutic vaccine, PepCan, for reducing head and neck squamous cell carcinoma recurrence.

Oncotarget·2026
Same journal

The anticancer effects of PCAIs in pancreatic cancer cells involve MAPK and PI3K/AKT pathways hyperactivation.

Oncotarget·2026
Same journal

Microenvironmental CTHRC1 has a pro-tumorigenic role in colorectal cancer.

Oncotarget·2026
See all related articles

Related Experiment Video

Updated: Mar 3, 2026

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

1.3K

Variable step size methods for solving simultaneous algebraic reconstruction technique (SART)-type cbct

Heui Chang Lee1,2, Bongyong Song3, Jin Sung Kim4

  • 1Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.

Oncotarget
|May 6, 2017
PubMed
Summary
This summary is machine-generated.

A new variable step-size (VS)-SART algorithm significantly speeds up Cone Beam Computed Tomography (CBCT) image reconstruction. This computationally efficient method, utilizing GPU acceleration, shows clinical feasibility for faster cancer patient imaging.

Keywords:
GPUIGRTSARTimage reconstructionweighted least squares

More Related Videos

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.6K
Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.5K

Related Experiment Videos

Last Updated: Mar 3, 2026

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

1.3K
Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.6K
Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.5K

Area of Science:

  • Medical Imaging
  • Computational Science
  • Radiology

Background:

  • Cone Beam Computed Tomography (CBCT) image reconstruction often relies on iterative algorithms like Simultaneous Algebraic Reconstruction Technique (SART).
  • While SART offers superior image quality and flexibility compared to analytical methods like Feldkamp-Davis-Kress (FDK), its computational intensity limits clinical application.
  • Intense computations in traditional SART algorithms hinder real-time or rapid clinical use.

Purpose of the Study:

  • To develop a computationally efficient SART-type algorithm for accelerated CBCT image reconstruction.
  • To demonstrate the clinical feasibility and improved speed of the novel algorithm in various reconstruction scenarios.
  • To enhance the speed of SART algorithms through optimized step-size calculation and parallel processing.

Main Methods:

  • Developed a variable step-size (VS)-SART algorithm incorporating Barzilai and Borwein step size computation for faster convergence.
  • Applied the VS-SART algorithm to numerical phantoms, physical phantoms, and cancer patient data for reconstruction.
  • Leveraged Graphics Processing Unit (GPU) parallel computing to further accelerate the reconstruction process.
  • Connected the SART algebraic problem to a statistical weighted least squares problem to enhance reconstruction speed.

Main Results:

  • The VS-SART algorithm demonstrated significantly enhanced reconstruction speed, requiring fewer iterations.
  • Clinical feasibility was confirmed through successful application to cancer patient CBCT data.
  • The combination of VS-SART and GPU acceleration resulted in substantial improvements in reconstruction efficiency.
  • The algorithm achieved superior image quality and flexibility in input measurements compared to FDK.

Conclusions:

  • The developed VS-SART algorithm offers a clinically feasible and significantly faster approach to CBCT image reconstruction.
  • This accelerated method holds promise for improving workflow efficiency in radiation oncology and other clinical applications.
  • The integration of adaptive step-size calculation and GPU computing represents a major advancement in iterative reconstruction techniques.