Related Experiment Video
Updated: Mar 2, 2026

An Isolated Working Heart System for Large Animal Models
Published on: June 11, 2014
Validation of the No Objective Testing Rule and Comparison to the HEART Pathway
Jason P Stopyra1, Chadwick D Miller1, Brian C Hiestand1
1Department of Emergency Medicine, Wake Forest School of Medicine, Winston-Salem, NC.
Background:
The no objective testing rule (NOTR) is a decision aid designed to safely identify emergency department (ED) patients with chest pain who do not require objective testing for coronary artery disease.
Objectives:
The objective was to validate the NOTR in a cohort of U.S. ED patients with acute chest pain and compare its performance to the HEART Pathway.
Methods:
A secondary analysis of 282 participants enrolled in the HEART Pathway randomized controlled trial was conducted. Each patient was classified as low risk or at risk by the NOTR. Sensitivity for major adverse cardiac events (MACE) at 30 days was calculated in the entire study population. NOTR and HEART Pathways were compared among patients randomized to the HEART Pathway in the parent trial using McNemar's test and the net reclassification improvement (NRI).
Results:
Major adverse cardiac events occurred in 22/282 (7.8%) participants, including no deaths, 16/282 (5.6%) with myocardial infarction (MI), and 6/282 (2.1%) with coronary revascularization without MI. NOTR was 100% (95% confidence interval [CI] = 84.6%-100%) sensitive for MACE and identified 78/282 patients (27.7%, 95% = CI 22.5-33.3%) as low risk. In the HEART Pathway arm (n = 141), both NOTR and HEART Pathway identified all patients with MACE as at risk. Compared to NOTR, the HEART Pathway was able to correctly reclassify 27 patients without MACE as low risk, yielding a NRI of 20.8% (95% CI = 11.3%-30.2%).
Conclusions:
Within a U.S. cohort of ED patients with chest pain, the NOTR and HEART Pathway were 100% sensitive for MACE at 30 days. However, the HEART Pathway identified more patients suitable for early discharge than the NOTR.
More Related Videos
Related Concept Videos
Heart Failure IV: Classification and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pathophysiology of Cardiac Performance
Heart Failure II: Pathophysiology
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...

