Transthoracic Echocardiography versus Computed Tomography for Ascending Aortic Measurements in Patients with Bicuspid
Jae Yoon Park1, Thomas A Foley2, Crystal R Bonnichsen1
1Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota.
Background:
Ascending aorta dilatation is common in bicuspid aortic valve (BAV). The aim of this study was to investigate agreement of transthoracic echocardiographic (TTE) measurement of the sinuses of Valsalva and the tubular mid-ascending aorta (Asc-Ao) compared with electrocardiographically gated computed tomographic angiographic (CTA) assessment in patients with BAV.
Methods:
Fifty-three patients with BAV (mean age, 54 ± 14 years; 74% men) who underwent both TTE and CTA imaging for ascending aortic assessment were retrospectively identified. All studies were measured de novo by experts. TTE measurements were obtained at the sinuses and the Asc-Ao, at both systole and end-diastole, using both leading edge-to-leading edge (L-L) and inner edge-to-inner edge (I-I) methods in the parasternal long-axis (LAX) view. The sinuses were also measured in the parasternal short-axis (SAX) view using the same methods plus mid-diastole. CTA measurements were obtained in diastole using outer wall-to-outer wall (O-O) and inner wall-to-inner wall (I-I) methods. Correlation and agreement between the two imaging modalities were assessed using Lin correlation and Bland-Altman analysis, respectively.
Results:
Compared with CTA O-O maximum sinuses diameter, the best correlation and agreement were obtained using the TTE SAX mid-diastolic L-L method (ρ = 0.89, 2.6 ± 2.3 mm, respectively). Compared with CTA O-O maximum Asc-Ao diameter, the TTE LAX systolic L-L method (ρ = 0.93, 1.3 ± 2.5 mm) was best. Compared with CTA I-I maximum sinuses diameter, the TTE SAX mid-diastole L-L method (ρ = 0.95, 0.6 ± 2.2 mm) was unbiased. Compared with CTA I-I maximum Asc-Ao diameter, the TTE LAX end-diastolic L-L method (ρ = 0.95, 0.6 ± 2.4 mm) was unbiased.
Conclusions:
In patients with BAV aortopathy, unbiased agreement between CTA and TTE imaging can be obtained between the CTA I-I method and TTE SAX mid-diastolic L-L method for the sinuses and the TTE LAX end-diastolic L-L method for the Asc-Ao. When using the CTA O-O method, the best agreement is obtained with the TTE SAX mid-diastolic L-L method for the sinuses (bias ∼2 mm) and the TTE LAX systolic L-L method (bias ∼1 mm) for the Asc-Ao.
More Related Videos
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...