Related Experiment Video
Updated: Mar 2, 2026

09:31
Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
1.7K
Optimal Z-Score Use in Surgical Decision-Making in Pulmonary Atresia With Intact Ventricular Septum.
Mark Nelson Awori1, Nikita P Mehta1, Frederick O Mitema1
11 Department of Surgery, School of Medicine, College of Health Sciences, University of Nairobi, Nairobi, Kenya.
Summary
Tricuspid valve annulus z-scores are crucial for pulmonary atresia with intact ventricular septum repair decisions. Variations in z-score data sets may explain differing outcomes for biventricular repair, potentially impacting surgical choices.
Area of Science:
- Pediatric Cardiology
- Congenital Heart Surgery
- Medical Imaging & Diagnostics
Background:
- Tricuspid valve annulus z-scores are critical in surgical decisions for pulmonary atresia with intact ventricular septum.
- Existing literature shows significant variation in reported z-score cutoffs for successful biventricular repair.
Purpose of the Study:
- To investigate if differing z-score data sets contribute to the wide range of reported cutoffs for biventricular repair in pulmonary atresia with intact ventricular septum.
- To clarify the impact of z-score data set selection on surgical pathway allocation.
Main Methods:
- A PubMed search was conducted using specific terms for pulmonary atresia, intact septum, and z-scores.
- Included studies that specified the z-score data set used in patients undergoing biventricular repair.
- Analyzed data from 13 articles encompassing 1,392 patients.
Main Results:
- Out of 1,392 patients, 410 (29.5%) underwent successful biventricular repair.
- Mean tricuspid valve annulus z-scores in biventricular repair patients varied widely (-0.53 to -5.1) across three reported data sets.
- After data set correction, no study reported a mean z-score below -2.8, and 83.3% reported means above -1.7.
Conclusions:
- Discrepancies in tricuspid valve annulus z-score data sets likely contribute to variations in reported biventricular repair cutoffs.
- Inconsistent use of z-score data sets may lead to suboptimal surgical approach selection for patients with pulmonary atresia and intact ventricular septum.
More Related Videos
Related Concept Videos
z Scores and Area Under the Curve
19.8K
z scores are the standardized values obtained after converting a normal distribution into a standard normal distribution. A z score is measured in units of the standard deviation. The z score tells you how many standard deviations the value x is above (to the right of) or below (to the left of) the mean, μ. Values of x that are larger than the mean have positive z scores, and values of x that are smaller than the mean have negative z scores. If x equals the mean, then x has a z score of...
19.8K
Critical Values
10.5K
A critical value is a definite value obtained from a particular probability distribution at a predecided confidence level (or a predecided significance level) for a given population parameter. The critical value provides demarcation that separates the sample statistics that are likely to occur from the ones that are unlikely to occur based on the given probability distribution and the population parameter to be estimated. The critical value for normal distribution is obtained from the z...
10.5K