Background:
We examined the reproducibility of differences in ambulatory blood pressure (BP) monitoring (ABPM) phenotypes and other parameters (sustained hypertension, masked hypertension, nocturnal hypertension, and nondipping) between African Americans and Whites.
Methods:
A total of 420 participants untreated for hypertension attended 2 research visits 1 week apart during which traditional office BP averages and ABPM session averages were determined. We computed percent agreement in ABPM phenotypes across the 2 visits stratified by race and associated kappa statistics with 95% confidence intervals.
Results:
Whites on average were older, more likely to be male, and had a higher body mass index. There was no significant difference in sleep quality as defined by sleep diary between the 2 races. There were also no significant differences between races in the proportions of participants with sustained hypertension, sustained normotension, or masked hypertension at either testing session. The prevalence of nocturnal hypertension was 59% vs. 75% (P = 0.012) at session 1 and 59% vs. 73% (P = 0.024) at session 2 for Whites and African Americans, respectively, with moderate reproducibility for both (kappas 0.45 and 0.44). Nocturnal BP nondipping had a prevalence 29% vs. 53% (P < 0.001) at session 1 and 29% vs. 47% (P = 0.004) at session 2 for Whites and African Americans, respectively, with fair reproducibility (kappas 0.28 and 0.29).
Conclusions:
Our findings support that African Americans indeed exhibit a greater preponderance of abnormal nocturnal BP patterns than Whites. Our work is some of the first to demonstrate that these abnormal patterns are modestly reproducible.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)