Related Experiment Video
Updated: Mar 1, 2026

Subcostal Specimen Removal in Completely Portal Robotic Lobectomy
Published on: April 19, 2024
CO2 insufflation versus air insufflation for endoscopic submucosal dissection: A meta-analysis of randomized
Xuan Li1,2, Hao Dong3, Yifeng Zhang1,2
1Department of Gastroenterology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
Background:
Carbon dioxide (CO2) insufflation is increasingly used for endoscopic submucosal dissection (ESD) owing to the faster absorption of CO2 as compared to that of air. Studies comparing CO2 insufflation and air insufflation have reported conflicting results.
Objectives:
This meta-analysis is aimed to assess the efficacy and safety of use of CO2 insufflation for ESD.
Methods:
Clinical trials of CO2 insufflation versus air insufflation for ESD were searched in PubMed, Embase, the Cochrane Library and Chinese Biomedical Literature Database. We performed a meta-analysis of all randomized controlled trials (RCTs).
Results:
Eleven studies which compared the use of CO2 insufflation and air insufflation, with a combined study population of 1026 patients, were included in the meta-analysis (n = 506 for CO2 insufflation; n = 522 for air insufflation). Abdominal pain and VAS scores at 6h and 24h post-procedure in the CO2 insufflation group were significantly lower than those in the air insufflation group, but not at 1h and 3h after ESD. The percentage of patients who experienced pain 1h and 24h post-procedure was obviously decreased. Use of CO2 insufflation was associated with lower VAS scores for abdominal distention at 1h after ESD, but not at 24h after ESD. However, no significant differences were observed with respect to postoperative transcutaneous partial pressure carbon dioxide (PtcCO2), arterial blood carbon dioxide partial pressure (PaCO2), oxygen saturation (SpO2%), abdominal circumference, hospital stay, white blood cell (WBC) counts, C-Reactive protein (CRP) level, dosage of sedatives used, incidence of dysphagia and other complications.
Conclusion:
Use of CO2 insufflation for ESD was safe and effective with regard to abdominal discomfort, procedure time, and the residual gas volume. However, there appeared no significant differences with respect to other parameters namely, PtcCO2, PaCO2, SpO2%, abdominal circumference, hospital stay, sedation dosage, complications, WBC, CRP, and dysphagia.
More Related Videos
04:30Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
07:54Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...