Simultaneous use of linear and nonlinear gradients for B1+ inhomogeneity correction
Koray Ertan1,2, Ergin Atalar1,2
1National Magnetic Resonance Research Center (UMRAM), Bilkent University, Bilkent, Ankara, Turkey.
Abstract:
The simultaneous use of linear spatial encoding magnetic fields (L-SEMs) and nonlinear spatial encoding magnetic fields (N-SEMs) in B1+ inhomogeneity problems is formulated and demonstrated with both simulations and experiments. Independent excitation k-space variables for N-SEMs are formulated for the simultaneous use of L-SEMs and N-SEMs by assuming a small tip angle. The formulation shows that, when N-SEMs are considered as an independent excitation k-space variable, numerous different k-space trajectories and frequency weightings differing in dimension, length, and energy can be designed for a given target transverse magnetization distribution. The advantage of simultaneous use of L-SEMs and N-SEMs is demonstrated by B1+ inhomogeneity correction with spoke excitation. To fully utilize the independent k-space formulations, global optimizations are performed for 1D, 2D RF power limited, and 2D RF power unlimited simulations and experiments. Three different cases are compared: L-SEMs alone, N-SEMs alone, and both used simultaneously. In all cases, the simultaneous use of L-SEMs and N-SEMs leads to a decreased standard deviation in the ROI compared with using only L-SEMs or N-SEMs. The simultaneous use of L-SEMs and N-SEMs results in better B1+ inhomogeneity correction than using only L-SEMs or N-SEMs due to the increased number of degrees of freedom.
Related Concept Videos
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
NMR Spectrometers: Resolution and Error Correction