Related Experiment Video
Updated: Mar 1, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Right ventricular apical versus non-apical implantable cardioverter defibrillator lead: A systematic review and
Jalaj Garg1, Rahul Chaudhary2, Neeraj Shah1
1Division of Cardiology, Lehigh Valley Health Network, Allentown, PA.
Introduction:
We aimed to study the effect of right ventricular implantable cardioverter defibrillator (ICD) lead positioning on clinical outcomes in patients undergoing ICD placement.
Methods:
A systematic literature search was performed using PubMed, EMBASE, Web of Science, and Cochrane Central Register of Controlled Trials to identify clinical trials comparing outcomes in patients with ICD leads in apical and non-apical positions. The primary outcome of our study was death at 1-year follow-up. Secondary outcomes studied were "death at 3years", "total number of shocks", "appropriate shocks", "inappropriate shocks" and "cut-to-suture time".
Results:
We analyzed a total of 3731 patients (2852 in apical and 879 in non-apical ICD groups) enrolled in 4 clinical trials. No significant difference was observed between the apical and non-apical ICD groups in all-cause mortality at 1year (OR 0.88; 95% CI 0.51-1.49, p=0.63; I2=5.32%). Similarly, no differences were seen between the two groups in death at 3years (OR=0.76; 95% CI 0.56-1.04, p=0.08; I2=0%), total number of shocks (OR 0.99; 95% CI 0.81-1.22, p=0.95; I2=0%), appropriate shocks (OR 1.00; 95% CI 0.79-1.27, p=0.99; I2=0%), inappropriate shocks (OR 0.98; 95% CI 0.70-1.37, p=0.91; I2=0%) and cut-to-suture time (Standard mean difference=-0.03; 95% CI -0.20 to 0.14, p=0.73; I2=0%). No publication bias was seen.
Conclusion:
Non-apical RV ICD lead implantation is non-inferior to traditional RV apical position with no significant differences in mortality, total number of shocks, appropriate shocks, inappropriate shocks and procedural time.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...