Interferometric characterization of rotation stages for X-ray nanotomography
Tomaš Stankevič1, Christer Engblom2, Florent Langlois2
1MAX IV Laboratory, Lund University, P.O. Box 118, SE-221 00 Lund, Sweden.
Abstract:
The field of three-dimensional multi-modal X-ray nanoimaging relies not only on high-brilliance X-rays but also on high-precision mechanics and position metrology. Currently available state-of-the-art linear and rotary drives can provide 3D position accuracy within tens to hundreds of nm, which is often insufficient for high resolution imaging with nanofocused X-ray beams. Motion errors are especially troublesome in the case of rotation drives and their correction is more complicated and relies on the metrology grade reference objects. Here we present a method which allows the characterisation and correction of the radial and angular errors of the rotary drives without the need for a highly accurate metrology object. The method is based on multi-probe error separation using fiber-laser interferometry and uses a standard cylindrical sample holder as a reference. The obtained runout and shape measurements are then used to perform the position corrections using additional drives. We demonstrate the results of the characterization for a piezo-driven small rotation stage. The error separation allowed us to measure the axis runout to be approximately ±1.25 μm, and with active runout compensation this could be reduced down to ±42 nm.
More Related Videos
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
X-ray Imaging
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...