Related Experiment Video
Updated: Mar 1, 2026

Author Spotlight: Advancing Biopsy Techniques with Transesophageal Ultrasound
Published on: November 21, 2023
Catheter probe endoscopic ultrasonography by using cold lubricating jelly-filled method for esophageal subepithelial
1Department of Internal Medicine, Gangneung Asan Hospital, Ulsan University College of Medicine, Gangneung, Korea.
Abstract:
Catheter probe endoscopic ultrasonography (C-EUS) by ultrasonographic jelly-filled method has been used to evaluate esophageal subepithelial tumors (SETs). Ultrasonographic jelly is safe on the skin, but its internal safety has not been demonstrated. The jelly stored at room temperature is easily injected into the esophagus through the instrument channel of the endoscope. However, using jelly stored at room temperature remains problematic because the jelly is drained rapidly. We used cold lubricating jelly and an intravenous extension tube to resolve these problems. In this study, we evaluated the safety and efficacy of cold lubricating jelly-filled method. The medical records of patients who underwent C-EUS by using water or cold lubricating jelly-filled method for esophageal SETs from March 2013 to September 2016 in Gangneung Asan hospital were reviewed. Clinical characteristics and EUS findings were evaluated retrospectively. Image quality and procedure time between water and cold lubricating jelly-filled method were compared retrospectively. This study included 138 patients (74 males, 64 females) with esophageal SET with a mean age of 57.1 ± 11.1 years. Thirty-four patients had lesions in the upper esophagus, 58 patients had lesions in the middle esophagus, and 46 patients had lesions in the lower esophagus. The EUS diagnoses were leiomyoma (82.6%), hemangioma (4.3%), extrinsic compressive lesion (3.6%), granulosa cell tumor (2.9%), ectopic calcification (1.4%), cyst (1.4%), lipoma (0.7%), varix (0.7%), and inconclusive lesion (2.2%). The mean image score in the cold lubricating jelly filled-method group was higher than that in the water-filled method group (3.2 ± 0.7 vs. 2.8 ± 0.7, P = 0.002). The procedure time in the cold lubricating jelly filled-method group was shorter than that in the water-filled method group (10 minutes 27 seconds ± 4 minutes 22 seconds versus 13 minutes 20 seconds ± 6 minutes 20 seconds, P = 0.045). No procedure-related complication was observed. C-EUS using the cold lubricating jelly-filled method seems to provide better image quality and shorter procedure time compared with C-EUS using the water-filled method.
Related Concept Videos
Urologic Endoscopic Procedure: Cystoscopic Examination
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures II: Colonoscopy
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...