Impact of light transmittance mode on polymerisation kinetics in bulk-fill resin-based composites
Related Experiment Video
Updated: Mar 1, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
1Department of Operative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-Universität München, Goethestr. 70, D-80336 Munich, Germany.
Objectives:
to determine the mode of light transmission and its impact on the polymerisation kinetic in modern bulk-fill resin-based composites (B-RBC).
Materials And Methods:
Four low-viscosity methacrylate-based and one high-viscosity ormocer-based B-RBCs were considered. One material was available in three different shades that were all analyzed. Polymerization kinetic and light transmittance were assessed in 2 and 4mm specimen depths. Incident and transmitted irradiance and radiant exposure were measured in real-time on a laboratory-grade spectrometer.
Results:
A progressive enhanced light transmittance during polymerisation was identified in all materials except for TetricEvoFlow BulkFill, which became progressively opaque in all shades. One-way ANOVA and multivariate analysis (α=0.05) were performed. The parameter material has a significant (p<0.001) effect on DC (ηP2=0.856) and light transmittance parameters (irradiance, ηP2=0.965; radiant exposure, ηP2=0.956); specimen depth influences only transmittance (ηP2=0.978; 0.980). DC variation in time was best described by an exponential sum function (R2>0.95), differentiating between the gel- and the glass-phase and revealing a faster initiation of polymerization and a slower transition into the glass-phase by lowering the filler volume. Depth retarded the transition into the glass-phase, but did not alter DC measured 300s post-irradiation. Moderate inverse correlation was identified among DC and filler volume% (-0.646) or filler weight% (-0.403), while no correlation among DC and light transmittance (p=0.141; 0.125). The maximal rate of carbon-carbon double bond conversion varied within the analyzed materials but was independent from specimen's depths.
Conclusions:
Light transmission changes during polymerization do not alter polymerization kinetics in modern B-RBCs. DC 300s post-irradiation was maintained with depth, while light was attenuated, the faster the more translucent the material was. DC and quality of curing cannot be related to light transmittance in B-RBCs.
Related Concept Videos
Step-Growth Polymerization: Overview
Many natural and synthetic polymers are produced by...
Molecular Weight of Step-Growth Polymers
As the step-growth polymerization involves step-wise condensation of monomers, the molecular weight also builds up eventually. Consequently, high molecular weight polymers are obtained at the late stages of the polymerization, where 99% of monomers have been consumed.
The extent of the...
Polymer Classification: Stereospecificity
Variables Affecting Phosphorescence and Fluorescence