Related Experiment Video
Updated: Mar 1, 2026

Author Spotlight: Assessing the Cardiovascular Profile of Patients with Metabolic Syndrome
Published on: September 27, 2024
Harmonic analysis of peripheral pulse for screening subjects at high risk of diabetes
G D Jindal1, Rajesh Kumar Jain2, Sushma N Bhat3
1a Bio-Medical Engineering Department , MGMCET , Navi-Mumbai , India.
Abstract:
Power spectral density (PSD) of peripheral pulses in human has been investigated in the past for its clinical applications. Continuing the efforts, data acquired using Peripheral Pulse Analyser in research projects sponsored by Board of Research in Nuclear Sciences in 207 control subjects, 18 descendants of diabetic patients and 22 patients with systemic hypertension have been subjected to PSD analysis for its study of harmonics. Application software, named Pulse Harmonic Analyser specifically developed for this work, selected 131,072 samples from each data file, obtained PSD, derived 52 PHA parameters and saved them in an Excel sheet. Coefficient of variation in control data was reduced significantly by application of Central Limit Theorem, which enabled use of parametric methods for statistical analysis of the observations. Data in hypertensive patients have shown significant difference in comparison to that of controls in eight parameters at low values of α and β. Data in offspring of diabetic patients also have shown significant difference in one parameter indicating its usefulness in screening subjects with genetic disposition of acquiring Type-II Diabetes. PHA analysis has also yielded sub-harmonic components, which are related to combined variability in the heart rate, pulse volume and pulse morphology and has a potential to become method of choice for real time variability monitoring.
More Related Videos
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: