Related Experiment Video
Updated: Feb 28, 2026

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Fabrication of porous ionic liquid polymer as solid-phase microextraction coating for analysis of organic acids by
1Research Center of Analytical Instrumentation, Analytical & Testing Center, Sichuan University, Chengdu 610065, China.
Abstract:
A kind of porous ionic liquid polymer was designed as coating material for solid-phase microextraction (SPME) fibers to extract polar organic acids. The synthesized ionic liquids (1-vinyl-3-(4-vinyl-benzyl)imidazolium chloride) were polymerized in the presence of azobisisobutyronitrile (AIBN), and subsequently coated on stainless steel wires with physical adhesion. To guarantee the adhesion between coating and the surface of stainless steel wires, micro-wave induced plasma was applied to modify the stainless steel wires. The derivatives of extracted organic acids were analyzed by gas chromatography combined with mass spectrometry (GC-MS) with N-tert-Butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA) as the derivatization reagent. Under the optimal condition, a calibration study was carried out to evaluate the performance of the SPME fibers. The calibration curves were linear (R2>0.99) in the range from 0.01μg/ml to 1μg/ml for six organic acids. Detection limits were detected down to 0.07ng/ml. To further validate the extraction efficiency of the fibers, experiments were conducted in comparison with commercial fibers. Lower LOD and LOQ values were obtained by the in-house fabricated fibers especially for polyatomic acids. Good repeatability (RSD≤16%) and fiber-to-fiber reproducibility (RSD≤20%) were obtained. The acceptable recovery of the spiked grape wine samples ranged from 78.19% to 98.11%. Additionally, long lifetime and good durability of the fibers have been demonstrated. The performance of the established SPME-GC-MS method for analysis of organic acids was shown to be greatly improved in comparison to the direct HPLC/CE method or other SPME materials as reported in the literature. In summary, a feasible and effective approach has been demonstrated to fabricate the in-house fabricated fibers based on porous ionic liquid polymers, which were proved to be advantageous and sensitive for extraction of polar organic acids. Simultaneously, application of the SPME derivatization GC-MS method for analysis of organic acids has been successfully verified as feasible and reliable.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion Exchange
Extraction: Advanced Methods
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Ion-Exchange Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...

