Purpose:
Brachytherapy (BT) techniques have historically used a two-dimensional nonvolumetric (NV) system involving dose prescribed to a point fixed in space. We compared dosimetric, toxicity, and oncologic outcomes for volumetric planning (3DV) versus CT point-based planning.
Methods And Materials:
Patients treated with external beam radiation therapy and high dose rate (HDR) intracavitary BT were included (n = 71). Patients planned with NV BT treated from 2009 to 2011 (n = 37) were compared to patients planned with 3DV BT treated from 2012 to 2014 (n = 34). Investigators delineated volumes for organs at risk clinical target volumes for the 2009-2011 NV cohort. Acute and chronic toxicity data were graded.
Results:
The mean HDR clinical target volume D90 received in the NV and 3DV cohorts were significantly different (p < 0.001). The mean dose to point A was significantly higher in the NV cohort than in the 3DV cohort (p < 0.001). There were significantly more Grade 3 or higher gastrointestinal toxicities in the NV cohort (p = 0.048). There was a nonsignificant trend toward improved oncologic outcomes for patients undergoing CT-based planning.
Conclusions: