Related Experiment Video
Updated: Feb 28, 2026

Individualized Reconstitution of Human Milk Microbiota: A Feasible Approach in Real-World Settings
Published on: February 7, 2025
Nutrient Profiles and Volatile Odorous Compounds of Raw Milk After Exposure to Electron Beam Pasteurizing Doses
Lindsay R Ward1,2, Chris R Kerth1,3, Suresh D Pillai1,2,4
1Natl. Center for Electron Beam Research - an IAEA Collaborating Centre for Electron Beam Technology, Texas A&M Univ., 400 Discovery Drive, College Station, TX, 77843-2472, U.S.A.
Abstract:
Raw milk is known to contain relatively high numbers of microorganisms, some of which include microbial pathogens. Electron beam (eBeam) processing is a nonthermal pasteurization food processing technology. The underlying hypothesis was that eBeam processing will not negatively influence the composition, nutrient content, and aroma profile of raw milk. Raw milk samples were exposed to eBeam doses of 1 and 2 kGy, since our studies had shown that 2 kGy is suitable for raw milk pasteurization. The untreated and eBeam-treated raw milk samples were analyzed to detect changes in lactose, vitamin B2 , vitamin B12 , and calcium concentrations. The possible breakdown of casein and whey proteins and lipid oxidation were investigated along with the formation of volatile aroma compounds. Even though vitamin B2 showed a 31.6% decrease in concentration, the B2 content in eBeam-pasteurized raw milk met all USDA nutritional guidelines. Even though there were no indications of lipid oxidation after the 2.0-kGy eBeam treatment, there was lipid oxidation (58%) after 7 d of refrigerated storage. However, based on the GC-olfactory analysis, the lipid oxidation did not necessarily result in the development of a wide variety of off-odors.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...

