Related Experiment Video
Updated: Feb 28, 2026

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
Published on: May 3, 2019
Evidence for revision of the evaluated half-life of 207Bi
1National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD 20899-8462, USA.
Abstract:
The National Institute of Standards and Technology (NIST) compared the measured full-energy peak efficiency obtained from a large set of sources to that of a 207Bi source obtained using three different half-life values. The values of the half-life used for this comparison are published in the Decay Data Evaluation Project (32.9 ± 1.4) years and the Evaluated Nuclear Structure Data File (31.55 ± 0.04) years, and in a recent NIST publication (31.20 ± 0.05) years (or (11395 ± 18) days).
Related Concept Videos
Radioactive Decay and Radiometric Dating
Nuclear Stability
To hold positively charged protons together...
Pharmacokinetic–Pharmacodynamic Relationship: Influence of Elimination Half-Life on Effect Duration
Half-life of a Reaction
Nuclear Transmutation
Isotopes and Radioisotopes
An isotope containing...