Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Feasibility of Combined Doppler-ECG Assessment of Internal Jugular Veins
Inge Dierickx1, Simon Van Hooland2, Kathleen Tomsin3
1Department of Obstetrics and Gynecology, Algemeen Ziekenhuis Sint Lucas, Ghent, Belgium; Department of Physiology, University Hasselt, Hasselt, Belgium.
Abstract:
A standardized combined Doppler-electrocardiography technique was developed for measurement of the triphasic waveform characteristics in the internal jugular vein. Flow velocities at the A, X, V and Y peaks, the RR interval and the PA and RX times were measured. From these the venous impedance index ([X-A]/X) and the ratios PA/RR and RX/RR were calculated. Six measurements were performed at three different locations by two ultrasonographers in 21 randomly selected pregnant and non-pregnant women. Statistical models proved the feasibility and reproducibility of this technique, with the highest concordance correlation coefficients in the right distal internal vein. Bootstrapping revealed that repeating the measurements more than four times would not significantly enhance the precision of the estimated mean. Concordance correlation coefficients for the venous impedance index, PA time and PA/RR ratio were >0.63 for all three locations, proving their possible use in ongoing and future studies, analogous to previous studies in kidney and liver.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: