Positron-emission tomography enhancement after vocal fold injection medialization
Nazaneen Grant1, Richard J Wong, Dennis H Kraus
1Department of Otolaryngology, New York University School of Medicine, New York, NY, USA.
Positron-emission tomography (PET) scans may show increased 18F-fluorodeoxyglucose (FDG) uptake after vocal fold augmentation. This variability in FDG uptake should be considered when interpreting PET scans for potential malignancy.
Area of Science:
- Otolaryngology
- Nuclear Medicine
- Radiology
Background:
- Positron-emission tomography (PET) scans using 18F-fluorodeoxyglucose (FDG) are crucial for diagnosing malignancy.
- Increased FDG uptake in vocal folds after augmentation medialization can mimic malignancy, potentially leading to misdiagnosis.
Purpose of the Study:
- To investigate the extent and variability of FDG uptake in vocal folds following augmentation medialization.
- To determine if there is a correlation between FDG uptake differences and the time elapsed since vocal fold augmentation.
Main Methods:
- Retrospective chart review of 15 adult patients who underwent unilateral vocal fold augmentation and subsequent PET scans.
- Comparison of standard uptake values (SUV) between injected and noninjected vocal folds using the Wilcoxon signed-rank test.
- Spearman rank correlation analysis to assess the relationship between SUV differences and time to PET scan.
Main Results:
- The mean SUV in injected vocal folds (3.70) was higher than in noninjected folds (2.97), but the difference was not statistically significant (p = 0.34).
- No significant correlation was found between the difference in PET uptake and the time between injection and the PET scan (r = -0.24, p = 0.34).
- PET uptake after vocal fold augmentation is variable and can be substantially increased.
Conclusions:
- Vocal fold augmentation medialization can lead to variable and potentially significant increases in FDG uptake on PET scans.
- This increased uptake may mimic malignancy, impacting diagnostic accuracy.
- Clinicians should consider postsurgical changes when interpreting PET scans in patients with vocal fold augmentation.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...