Related Experiment Video
Updated: Feb 27, 2026

Deep Neuromuscular Blockade Leads to a Larger Intraabdominal Volume During Laparoscopy
Published on: June 25, 2013
Deep neuromuscular blockade improves surgical conditions during low-pressure pneumoperitoneum laparoscopic donor
D M D Özdemir-van Brunschot1, A E Braat2, M F P van der Jagt1
1Division of Vascular and Transplant Surgery, Department of Surgery, Radboud University Medical Centre, Geert Grooteplein-Zuid 10, 6525 GA, Nijmegen, The Netherlands.
Background:
Evidence indicates that low-pressure pneumoperitoneum (PNP) reduces postoperative pain and analgesic consumption. A lower insufflation pressure may hamper visibility and working space. The aim of the study is to investigate whether deep neuromuscular blockade (NMB) improves surgical conditions during low-pressure PNP.
Methods:
This study was a blinded randomized controlled multicenter trial. 34 kidney donors scheduled for laparoscopic donor nephrectomy randomly received low-pressure PNP (6 mmHg) with either deep (PTC 1-5) or moderate NMB (TOF 0-1). In case of insufficient surgical conditions, the insufflation pressure was increased stepwise. Surgical conditions were rated by the Leiden-Surgical Rating Scale (L-SRS) ranging from 1 (extremely poor) to 5 (optimal).
Results:
Mean surgical conditions were significantly better for patients allocated to a deep NMB (SRS 4.5 versus 4.0; p < 0.01). The final insufflation pressure was 7.7 mmHg in patients with deep NMB as compared to 9.1 mmHg with moderate NMB (p = 0.19). The cumulative opiate consumption during the first 48 h was significantly lower in patients receiving deep NMB, while postoperative pain scores were similar. In four patients allocated to a moderate NMB, a significant intraoperative complication occurred, and in two of these patients a conversion to an open procedure was required.
Conclusions:
Our data show that deep NMB facilitates the use of low-pressure PNP during laparoscopic donor nephrectomy by improving the quality of the surgical field. The relatively high incidence of intraoperative complications indicates that the use of low pressure with moderate NMB may compromise safety during LDN. Clinicaltrials.gov identifier: NCT 02602964.
Related Concept Videos
Skeletal Muscle Relaxants: Therapeutic Uses
Local Anesthetics: Clinical Application as Spinal Anesthesia
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...