Related Experiment Video
Updated: Feb 27, 2026

Closure of a Patent Foramen Ovale PFO: An Intervention Sequence
Published on: December 23, 2022
Asymptomatic late embolization of Amplatzer septal occluder device
Ranjit Kumar Nath1, Neeraj Pandit1
1Department of Cardiology, Dr. Ram Manohar Lohia Hospital and PGIMER, New Delhi-110001, India.
Abstract:
Atrial septal defects of Ostium Secundum type with suitable anatomy and margins are commonly closed with septal occluder devices. With the increasing number of catheterization laboratories and increasing availability of different devices, the device closure procedure is very commonly performed in different institutes. Embolization of the septal occluder is one of the most dreaded complications of this procedure, which usually occurs in the early hours or days after the procedure. We report a case of silent embolization of the Amplatzer septal occluder, detected seven months after its use to close an Ostium Secundum atrial septal defect, which was detected during pre-anaesthetic evaluation and echocardiography for non-cardiac surgery. The patient denied having any symptom in-between. The device was retrieved and the defect was closed surgically.
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Stenosis I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests