Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Computational and Memory Efficiency in Heartbeat Rate Detection: A Review of ECG and PPG Techniques.

Sensors (Basel, Switzerland)·2026
Same author

Denoising Physiological Signals: Assessment, Techniques, and Wearable Implementation.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

Correction: Evaluating the effectiveness of integrating biofeedback in the treatment of aggressive outbursts (BRET-IA2): A study protocol.

PloS one·2025
Same author

A Single-Button Mobility Platform for Cause-Effect Learning in Children with Cerebral Palsy: A Pilot Study.

Children (Basel, Switzerland)·2025
Same author

Evaluating the effectiveness of integrating biofeedback in the treatment of aggressive outbursts (BRET-IA2): A study protocol.

PloS one·2025
Same author

Emotional State Measurement Trial (EMOPROEXE): A Protocol for Promoting Exercise in Adults and Children with Cerebral Palsy.

Journal of personalized medicine·2024
Same journal

RETRACTED: Zhang et al. A Novel Framework for Reconstruction and Imaging of Target Scattering Centers via Wide-Angle Incidence in Radar Networks. <i>Sensors</i> 2025, <i>25</i>, 6802.

Sensors (Basel, Switzerland)·2026
Same journal

Enhancing Unsupervised Multi-Source Domain Adaptation for Person Re-Identification via Mixture of Experts and Graph-Based Relation.

Sensors (Basel, Switzerland)·2026
Same journal

Development of an Instrumented Glove for Palmar Pressure Assessment in Kayakers.

Sensors (Basel, Switzerland)·2026
Same journal

Development and Experimental Validation of an Autonomous IoT-Based Monitoring System for Real-Time Water Quality Assessment in the Amazon River.

Sensors (Basel, Switzerland)·2026
Same journal

Semi-Supervised Adversarial Learning Framework for Controller Area Network Bus Intrusion Detection.

Sensors (Basel, Switzerland)·2026
Same journal

Smart Optimization Method for Safety Signs in Innovative Manufacturing Environments Integrating Industrial Field IoT Sensors and Knowledge Graphs.

Sensors (Basel, Switzerland)·2026
See all related articles

Related Experiment Video

Updated: Feb 27, 2026

Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding
11:25

Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding

Published on: July 26, 2013

44.2K

Characterizing Computer Access Using a One-Channel EEG Wireless Sensor.

Alberto J Molina-Cantero1, Jaime Guerrero-Cubero2, Isabel M Gómez-González3

  • 1Departamento de Tecnología Electrónica, ETS Ingeniería Informática, Universidad de Sevilla, Campus de Reina Mercedes, Sevilla 41012, Spain. almolina@us.es.

Sensors (Basel, Switzerland)
|June 30, 2017
PubMed
Summary
This summary is machine-generated.

This study shows that mental attention can control computers, achieving over 70% accuracy in potential users. This brain-computer interface (BCI) offers an eye-gaze independent alternative for communication.

Keywords:
attentionbrain computer interfacecerebral palsylinear discriminant analysiswireless EEG sensor

More Related Videos

Recording Human Electrocorticographic ECoG Signals for Neuroscientific Research and Real-time Functional Cortical Mapping
13:32

Recording Human Electrocorticographic ECoG Signals for Neuroscientific Research and Real-time Functional Cortical Mapping

Published on: June 26, 2012

27.0K
A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare
06:34

A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare

Published on: July 7, 2023

3.3K

Related Experiment Videos

Last Updated: Feb 27, 2026

Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding
11:25

Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding

Published on: July 26, 2013

44.2K
Recording Human Electrocorticographic ECoG Signals for Neuroscientific Research and Real-time Functional Cortical Mapping
13:32

Recording Human Electrocorticographic ECoG Signals for Neuroscientific Research and Real-time Functional Cortical Mapping

Published on: June 26, 2012

27.0K
A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare
06:34

A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare

Published on: July 7, 2023

3.3K

Area of Science:

  • Neuroscience
  • Biomedical Engineering
  • Rehabilitation Technology

Background:

  • Developing non-invasive brain-computer interfaces (BCIs) is crucial for assistive technology.
  • Mental attention is a potential control signal for individuals with motor impairments.
  • Previous BCIs often rely on sensorimotor rhythms or slow cortical potentials.

Purpose of the Study:

  • To investigate the feasibility of using mental attention for computer access.
  • To evaluate the accuracy and usability of an attention-based BCI.
  • To compare performance between typically developed individuals and those with cerebral palsy (CP).

Main Methods:

  • Electroencephalography (EEG) recorded brain activity at Fp1 with a left ear reference.
  • Participants (7 typically developed, 3 with CP) modulated mental attention (high/low).
  • Linear discriminant analysis (LDA) classifier used attention levels; power bands were also analyzed.

Main Results:

  • Over 60% of participants achieved >70% accuracy using attention levels alone.
  • Including power bands did not enhance classification accuracy.
  • Individuals with CP reported higher fatigue (2.7/3) than controls (1.5/3).

Conclusions:

  • Mental attention is a viable BCI control signal, achieving comparable Information Transfer Rates (ITR) to other methods.
  • Optimal BCI use for communication boards requires limited pictograms (4-7) and a long scanning period (≈10s).
  • This attention-based BCI offers a promising eye-gaze independent alternative for computer access.