Related Experiment Video
Updated: Feb 27, 2026

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
An original piecewise model for computing energy expenditure from accelerometer and heart rate signals
Hector M Romero-Ugalde1,2, M Garnotel3, M Doron1,2
1University Grenoble Alpes, F-38000 Grenoble, France.
Objective:
Activity energy expenditure (EE) plays an important role in healthcare, therefore, accurate EE measures are required. Currently available reference EE acquisition methods, such as doubly labeled water and indirect calorimetry, are complex, expensive, uncomfortable, and/or difficult to apply on real time. To overcome these drawbacks, the goal of this paper is to propose a model for computing EE in real time (minute-by-minute) from heart rate and accelerometer signals.
Approach:
The proposed model, which consists of an original branched model, uses heart rate signals for computing EE on moderate to vigorous physical activities and a linear combination of heart rate and counts per minute for computing EE on light to moderate physical activities. Model parameters were estimated from a given data set composed of 53 subjects performing 25 different physical activities (light-, moderate- and vigorous-intensity), and validated using leave-one-subject-out. A different database (semi-controlled in-city circuit), was used in order to validate the versatility of the proposed model. Comparisons are done versus linear and nonlinear models, which are also used for computing EE from accelerometer and/or HR signals.
Main Results:
The proposed piecewise model leads to more accurate EE estimations ([Formula: see text], [Formula: see text] and [Formula: see text] J kg-1 min-1 and [Formula: see text], [Formula: see text], and [Formula: see text] J kg-1 min-1 on each validation database).
Significance:
This original approach, which is more conformable and less expensive than the reference methods, allows accurate EE estimations, in real time (minute-by-minute), during a large variety of physical activities. Therefore, this model may be used on applications such as computing the time that a given subject spent on light-intensity physical activities and on moderate to vigorous physical activities (binary classification accuracy of 0.8155).
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Energy and Power Signals
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...

